W DOC AIRBUS | TSM A320F

Failure of the CFDIU Detected by the ATC 2


TASK 31-32-00-810-875-A
Failure of the CFDIU Detected by the ATC 2


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313203
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 34-52-00-740-004
BITE Test of the ATC
3. Fault Confirmation
Subtask 31-32-00-865-123-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/ATC/25SH2K07
Subtask 31-32-00-740-194-A
B. Test
Do the BITE test of the ATC (system 2) AMM 34-52-00-740-004.
4. Fault Isolation
Subtask 31-32-00-810-124-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ATC2 : NO DATA FROM CFDIU:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 31-32-00-810-124-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CFDIU (1TW) / ATC2 (1SH2):
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 31-32-00-740-195-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:53 UTC