W DOC AIRBUS | TSM A320F

Failure of the CFDIU Detected by the RMP1


TASK 31-32-00-810-872-A
Failure of the CFDIU Detected by the RMP1


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-13-00-740-001
BITE Test of the Radio Management
ASM 313202
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-120-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUCOM/RMP/12RG1G10
Subtask 31-32-00-740-188-A
B. Test
Do the BITE test of the Radio Management (RMP 1) AMM 23-13-00-740-001.
4. Fault Isolation
Subtask 31-32-00-810-121-B
A. If the test gives the maintenance message CFDIU(1TW)/RMP1(1RG1):
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AA/2B, 2C to the first terminal block , ASM 313202.
Subtask 31-32-00-740-189-A
B. Do the test given in Para. 3.B.