Failure of the CFDIU Detected by the DMC 1


TASK 31-32-00-810-868-A
Failure of the CFDIU Detected by the DMC 1


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313202
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
3. Fault Confirmation
Subtask 31-32-00-865-116-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUEIS/DMC1/SPLY10WT1E11
49VUEIS/DMC1/SWTG21WT1E09
Subtask 31-32-00-740-180-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test (system 1) AMM 31-60-00-740-002.
Subtask 31-32-00-740-180-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-32-00-810-117-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC1 : NO CFDIU DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AA/2B, 2C to the first terminal block , ASM 313202.
Subtask 31-32-00-810-117-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CFDIU(1TW)/DMC1(1WT1)
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AA/2B, 2C to the first terminal block , ASM 313202.
Subtask 31-32-00-740-181-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:53 UTC