Failure of the CFDIU Detected by the VHF 2
TASK 31-32-00-810-867-A
Failure of the CFDIU Detected by the VHF 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-115-A
Subtask 31-32-00-810-116-B
[Rev.8 from Aug 2018]
2026.04.04 04:29:53 UTC
Failure of the CFDIU Detected by the VHF 2
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-12-00-740-001 | BITE Test of the VHF System |
| ASM 313203 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-115-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-178-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/VHF/2 | 2RC2 | L04 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/VHF/2 | 2RC2 | L04 |
Subtask 31-32-00-810-116-B
A. If the test gives the maintenance message CFDIU (1TW)/VHF2 (1RC2):
Subtask 31-32-00-740-179-A - replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
B. Do the test given in Para. 3.B.