Failure of the CFDIU Detected by the ILS 2


TASK 31-32-00-810-866-A
Failure of the CFDIU Detected by the ILS 2


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313203
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 34-36-00-740-002
BITE Test of the ILS
3. Fault Confirmation
Subtask 31-32-00-865-114-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCOM NAV/ILS/21RT2K09
Subtask 31-32-00-740-176-A
B. Test
Do the BITE test of the ILS (system 2) AMM 34-36-00-740-002.
4. Fault Isolation
Subtask 31-32-00-810-115-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ILS2 NO DATA FROM CFDIU:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 31-32-00-810-115-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message
CFDIU(1TW)/ILS2(2RT2) or CMC1(1TM1)/ILS2(1RT2):
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 31-32-00-740-177-A
B. Do the test given in Para. 3.B.