W DOC AIRBUS | TSM A320F

Failure of the CFDIU Detected by the DMC 2


TASK 31-32-00-810-864-A
Failure of the CFDIU Detected by the DMC 2


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313203
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
3. Fault Confirmation
Subtask 31-32-00-865-112-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUEIS/DMC2/SPLY10WT2Q08
121VUEIS/DMC2/SWTG21WT2R08
Subtask 31-32-00-740-172-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test (system 2) AMM 31-60-00-740-002.
Subtask 31-32-00-740-172-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-32-00-810-113-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC2 : NO CFDIU DATA :
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 31-32-00-810-113-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CFDIU(1TW)/DMC2(1WT2)
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 31-32-00-740-173-A
B. Do the test given in Para. 3.B.