W DOC AIRBUS | TSM A320F

Failure of the CFDIU Detected by the DME 2


TASK 31-32-00-810-861-A
Failure of the CFDIU Detected by the DME 2


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313203
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 34-51-00-740-002
BITE Test of the DME
3. Fault Confirmation
Subtask 31-32-00-865-109-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/DME/21SD2K06
Subtask 31-32-00-740-166-A
B. Test
Do the BITE test of the DME (system 2) AMM 34-51-00-740-002.
4. Fault Isolation
Subtask 31-32-00-810-110-A
A. If the test gives the maintenance message DME2 NO DATA FROM CFDIU:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 31-32-00-740-167-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:53 UTC