Loss of the Bus Output from the ECB to the CFDIU
TASK 31-32-00-810-849-A
Loss of the Bus Output from the ECB to the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-740-144-A 4. Fault Isolation
Subtask 31-32-00-810-097-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:51 UTC
Loss of the Bus Output from the ECB to the CFDIU
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313204 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-740-144-A 4. Fault Isolation
Subtask 31-32-00-810-097-A
A. If the test gives the maintenance message:
NO ECB DATA:
Subtask 31-32-00-740-145-A NO ECB DATA:
- replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the CFDIU (1TW) pins AA/10F, 10G to the first terminal block , ASM 313204.
B. Do the test given in Para. 3.