W DOC AIRBUS | TSM A320F

Loss of the Bus Output from the BMC 2 to the CFDIU


TASK 31-32-00-810-847-A
Loss of the Bus Output from the BMC 2 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313205
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-094-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL2HA2Z22
Subtask 31-32-00-740-140-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-095-A
A. If the test gives the maintenance message:
NO BMC 2 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/7F, 7G to the first terminal block , ASM 313205.
Subtask 31-32-00-740-141-A
B. Do the test given in Para. 3.B.