Loss of the Bus Output from the RA Transceiver 2 to the CFDIU
TASK 31-32-00-810-839-A
Loss of the Bus Output from the RA Transceiver 2 to the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-086-A
Subtask 31-32-00-810-087-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:50 UTC
Loss of the Bus Output from the RA Transceiver 2 to the CFDIU
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313203 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-086-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-124-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RAD ALTM/2 | 1SA2 | K12 |
Subtask 31-32-00-810-087-A
A. If the test gives the maintenance message:
NO RA 2 DATA:
Subtask 31-32-00-740-125-A NO RA 2 DATA:
- replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the CFDIU (1TW) pins AB/10H, 10J to the first terminal block , ASM 313203.
B. Do the test given in Para. 3.B.