Loss of the Bus Output from the ATC Transponder 2 to the CFDIU
TASK 31-32-00-810-835-A
Loss of the Bus Output from the ATC Transponder 2 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-082-A
Subtask 31-32-00-810-083-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:50 UTC
Loss of the Bus Output from the ATC Transponder 2 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313203 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| AMM 34-52-33-000-001 | Removal of the ATC/Mode S Transponder |
| AMM 34-52-33-400-001 | Installation of the ATC/Mode S Transponder |
Subtask 31-32-00-865-082-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-116-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/ATC/2 | 5SH2 | K07 |
Subtask 31-32-00-810-083-A
A. If the test gives the maintenance message NO ATC 2 DATA:
Subtask 31-32-00-740-117-A - replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the XPDR-ATC/MODE S, 2 [1SH2] , AMM 34-52-33-000-001 and AMM 34-52-33-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the ATC transponder 2 (1SH2) from pins AB/8H, 8J to pins AB/6C, 6D ASM 313203.
B. Do the test given in Para. 3.B.