Loss of the Bus 3 Output from the ADIRU 2 to the CFDIU
TASK 31-32-00-810-834-A
Loss of the Bus 3 Output from the ADIRU 2 to the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-081-A
Subtask 31-32-00-810-082-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:50 UTC
Loss of the Bus 3 Output from the ADIRU 2 to the CFDIU
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313203 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-081-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-114-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | ADIRS/ADIRU/2/26VAC AND AOA | 5FP2 | N08 |
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| 121VU | ADIRS/ADIRU/2/28VDC | 6FP2 | N04 |
Subtask 31-32-00-810-082-A
A. If the test gives the maintenance message NO IR 2 DATA:
Subtask 31-32-00-740-115-A - replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the CFDIU (1TW) pins AB/2D, 2E to the first terminal block , ASM 313203.
B. Do the test given in Para. 3.B.