W DOC AIRBUS | TSM A320F

Loss of the Bus 3 Output from the ADIRU 1 to the CFDIU


TASK 31-32-00-810-828-A
Loss of the Bus 3 Output from the ADIRU 1 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313202
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-075-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUNAV PROBES/ADIRU 1/AND AOA 1/26VAC5FP1F07
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
105VUADIRS/ADIRU1/28VDC6FP1C02
Subtask 31-32-00-740-102-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-076-A
A. If the test gives the maintenance message NO IR 1 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AA/2F, 2G to the first terminal block , ASM 313202.
Subtask 31-32-00-740-103-A
B. Do the test given in Para. 3.B.