W DOC AIRBUS | TSM A320F

Loss of the Bus Output from the ADF 1 Receiver to the CFDIU


TASK 31-32-00-810-827-A
Loss of the Bus Output from the ADF 1 Receiver to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313202
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-074-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUNAV/ADF/11RP1H14
** ON A/C NOT FOR ALL
49VUNAV/ADF/11RP1F09
Subtask 31-32-00-740-100-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-075-A
A. If the test gives the maintenance message NO ADF 1 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AA/12B,12C to the first terminal block , ASM 313202.
Subtask 31-32-00-740-101-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:49 UTC