W DOC AIRBUS | TSM A320F

Loss of the Bus Output from the SFCC 2 to the CFDIU


TASK 31-32-00-810-819-A
Loss of the Bus Output from the SFCC 2 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313205
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-066-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/HOT BUS/702PP SPLY5PB2D02
105VUELEC/HOT BUS/702PP SPLY12PB2E02
121VUFLIGHT CONTROLS/SLT FLP/2POS/IND2CNP16
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
Subtask 31-32-00-740-084-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-067-A
A. If the test gives the maintenance message NO SFCC 2 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from CFDIU (1TW) pins AB/4D, 4E to the first terminal block , ASM 313205.
Subtask 31-32-00-740-085-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:49 UTC