W DOC AIRBUS | TSM A320F

Loss of the Bus Output from the SFCC 1 to the CFDIU


TASK 31-32-00-810-817-A
Loss of the Bus Output from the SFCC 1 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313204
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-064-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUFLIGHT CONTROLS/SLT FLP/POS/IND 11CNB12
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
105VUELEC/HOT BUS/701PP SPLY5PB1D01
105VUELEC/HOT BUS/701PP SPLY12PB1E01
Subtask 31-32-00-740-080-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-065-A
A. If the test gives the maintenance message NO SFCC 1 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from CFDIU (1TW) pins AA/4F, 4G to the first terminal block , ASM 313204.
Subtask 31-32-00-740-081-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:49 UTC