Loss of the Output Bus from the SDCU or the CIDS Director(s) to the CFDIU
TASK 31-32-00-810-813-A
Loss of the Output Bus from the SDCU or the CIDS Director(s) to the CFDIU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-740-072-A 4. Fault Isolation
Subtask 31-32-00-810-061-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:48 UTC
Loss of the Output Bus from the SDCU or the CIDS Director(s) to the CFDIU
1. Possible Causes
- CFDIU [1TW]
- SDCU [10WQ]
wiring from the CFDIU (1TW) to the SDCU (10WQ) - DIR-CIDS, 1 [101RH]
- DIR-CIDS, 2 [102RH]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 26-17-34-000-001 | Removal of the Smoke-Detection Control Unit (SDCU) |
| AMM 26-17-34-400-001 | Installation of the Smoke-Detection Control Unit (SDCU) |
| AMM 31-32-00-740-009 | Read the AVIONICS STATUS on the MCDU |
| ASM 313204 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-740-072-A 4. Fault Isolation
Subtask 31-32-00-810-061-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message NO SDCU DATA:
Subtask 31-32-00-810-061-B ** ON A/C NOT FOR ALL - Replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- Replace the SDCU [10WQ] AMM 26-17-34-000-001 and AMM 26-17-34-400-001.
- Do a check and repair the
wiring from the CFDIU (1TW) to the SDCU (10WQ) from pins AA/11H,11J to pins AB/3C, 4C , ASM 313204.
A. If the test gives the maintenance message NO SDCU DATA or NO CIDS-SDF DATA:
Subtask 31-32-00-740-073-A - Replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- Replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- Replace the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- Do a check and repair the wiring from the CFDIU pins AA/11H,11J to the CIDS director 1 (101RH) pins AA/9G, 9H ASM 313204.
- Do a check and repair the wiring from the CFDIU pins AA/11H,11J to the CIDS director 2 (102RH) pins AA/9G, 9H ASM 313204.
B. Do the test given in Para. 3.