W DOC AIRBUS | TSM A320F

Loss of the Bus Output from the BCL 2 to the CFDIU


TASK 31-32-00-810-811-A
Loss of the Bus Output from the BCL 2 to the CFDIU


1. Possible Causes
  • CFDIU [1TW]
  • BCL-2 [1PB2]
  • wiring from the CFDIU (1TW) to the BCL 2 (1PB2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-38-34-000-001
Removal of the Battery Charge Limiter (BCL)
AMM 24-38-34-400-001
Installation of the Battery Charge Limiter (BCL)
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 313206
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
3. Fault Confirmation
Subtask 31-32-00-865-058-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
105VUELEC/BAT REF/BCL29PB2F02
105VUELEC/BAT BUS/REF/BCL28PB2J02
Subtask 31-32-00-740-068-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 31-32-00-810-059-A
A. If the test gives the maintenance message NO BCL 2 DATA:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) to the BCL 2 (1PB2) from pins AB/7B, 7C to pins A/T, U , ASM 313206.
Subtask 31-32-00-740-069-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:48 UTC