Loss of the Bus Output from the BCL 1 to the CFDIU
TASK 31-32-00-810-810-A
Loss of the Bus Output from the BCL 1 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-865-057-A
Subtask 31-32-00-810-058-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:48 UTC
Loss of the Bus Output from the BCL 1 to the CFDIU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-38-34-000-001 | Removal of the Battery Charge Limiter (BCL) |
| AMM 24-38-34-400-001 | Installation of the Battery Charge Limiter (BCL) |
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 313206 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-865-057-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-32-00-740-066-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 105VU | ELEC/BAT REF/BCL1 | 9PB1 | F01 |
| 105VU | ELEC/BAT BUS/REF/BCL1 | 8PB1 | G01 |
Subtask 31-32-00-810-058-A
A. If the test gives the maintenance message NO BCL 1 DATA:
Subtask 31-32-00-740-067-A - replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the BCL-1 [1PB1] , AMM 24-38-34-000-001 and AMM 24-38-34-400-001.
- do a check and repair the
wiring from the CFDIU (1TW) to the BCL1 (1PB1) from pins AA/7H, 7J to pins A/T, U , ASM 313206.
B. Do the test given in Para. 3.B.