W DOC AIRBUS | TSM A320F

Loss of the Bus 1 of the CFDIU Detected by the VOR 1


TASK 31-32-00-810-809-A
Loss of the Bus 1 of the CFDIU Detected by the VOR 1


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 313202
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
3. Fault Confirmation
Subtask 31-32-00-865-097-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUNAV/VOR/12RS1G13
Subtask 31-32-00-740-146-A
B. Test
Do the BITE test of the VOR/MKR (system 1) AMM 34-55-00-740-002.
4. Fault Isolation
Subtask 31-32-00-810-098-A
A. If the test gives the maintenance message VOR1 : NO DATA FROM CFDIU:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AA/2B, 2C to the first terminal block , ASM 313202.
Subtask 31-32-00-740-147-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:48 UTC