Failure of the CFDIU Backup
TASK 31-32-00-810-808-A
Failure of the CFDIU Backup
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-32-00-740-064-A 4. Fault Isolation
Subtask 31-32-00-810-057-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:48 UTC
Failure of the CFDIU Backup
1. Possible Causes
- CFDIU [1TW]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-740-003 | Ground Scanning of the CFDIU |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
Subtask 31-32-00-740-064-A 4. Fault Isolation
Subtask 31-32-00-810-057-A
A. If the test gives the maintenance message CFDIU BACKUP:
Subtask 31-32-00-740-065-A - replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
B. Do the test given in Para. 3.