W DOC AIRBUS | TSM A320F

Loss of Synchronization between the Clock and the CFDIU


TASK 31-21-00-810-808-A
Loss of Synchronization between the Clock and the CFDIU


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-21-00-750-002
Procedure to set the Clock
3. Fault Confirmation
Subtask 31-21-00-700-050-A
A. Test

   (1) Do a print-out of a post flight report:
ACTION
RESULT
On the MCDU:
On the MCDU:
1.Turn the BRT knob.
  • The MCDU comes on.
2.Push the MCDU MENU mode key.
  • The MCDU MENU page comes into view.
3.Push the line key adjacent to the CMS indication.
  • The MAINTENANCE MENU page comes into view.
4.Push the line key 1R adjacent to the PRINT indication.
  • The printer gives the post-flight report print-out.

   (2) Do a check of the time and the date:
  • In the post-flight report header, and
  • On the clock (2FS).
4. Fault Isolation
Subtask 31-21-00-810-058-A
A. If the time and/or the date in the post-flight report header are different from the time and/or the date shown on the clock:
Subtask 31-21-00-740-057-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:48 UTC