W DOC AIRBUS | TSM A320F

Failure of the Clock


TASK 31-21-00-810-801-A
Failure of the Clock


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-21-21-000-001
Removal of the Clock
AMM 31-21-21-400-001
Installation of the Clock
AMM 31-32-00-740-003
Ground Scanning of the CFDIU
3. Fault Confirmation
Subtask 31-21-00-865-050-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUCLOCK/NORM/SPLY6FSF11
121VUCLOCK/STBY/SPLY4FSN02
Subtask 31-21-00-740-050-A
B. Test
Do the ground scanning of the CFDIU AMM 31-32-00-740-003.
4. Fault Isolation
Subtask 31-21-00-810-050-A
A. If the test gives the maintenance message CLOCK:
Subtask 31-21-00-740-051-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:29:47 UTC