Failure of heated Overflow Nipple


TASK 30-72-00-810-802-A
Failure of heated Overflow Nipple


1. Possible Causes
  • THERMOSTAT-OVERFLOW NIPPLE [14DV]
  • OVERFLOW NIPPLE [13DV]
  • wiring
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
SPRAY - COOLING
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
ASM 307201
AMM 30-72-52-000-001
Removal of the Heated Fill/Drain Nipple 11DV and/or Overflow Nipple 13DV
AMM 30-72-52-400-001
Installation of the Heated Fill/Drain Nipple 11DV and/or Overflow Nipple 13DV
AMM 52-30-00-860-006
Open the Bulk Cargo-Compartment Door
3. Fault Confirmation
Subtask 30-72-00-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
   (2) Put an ACCESS PLATFORM 2M (6 FT) in position at the potable-water service panel 171AL.
   (3) Open the BULK cargo-compartment door AMM 52-30-00-860-006.
   (4) Open the sidewall panel 161DW to get access to the thermostat 14DV.
Subtask 30-72-00-865-055-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2001VUWATER SERVICE PANEL HEATER15DVD01
** ON A/C NOT FOR ALL
2001VUPOT/WASTE WIP SVCE PNL15DVE08
Subtask 30-72-00-710-052-A ** ON A/C NOT FOR ALL
C. Do this test:
ACTION
RESULT
1.At the potable-water service panel (inboard side):
  • apply SPRAY - COOLING on and around the thermostat 14DV for at least 10 seconds.
At the potable-water service panel (outboard side):
  • examine that the heated fill/drain nipple 13DV becomes warm.
4. Fault Isolation
Subtask 30-72-00-810-051-A ** ON A/C NOT FOR ALL
A. If the overflow nipple 13DV stayes cold:
   (1) If the fault continues:
     (a) If the fault continues:
  • check for the subsequent signals at the terminal block 7510VT7:
    - 115VAC at 7510VT7/F;
    - GND at 7510VT7/A.
       1 If one signal is missing:
Subtask 30-72-00-710-053-A ** ON A/C NOT FOR ALL
B. Do the test as given in Para. 3.C.
5. Close-up
Subtask 30-72-00-860-053-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
[Rev.8 from Aug 2018] 2026.04.04 04:29:47 UTC