W DOC AIRBUS | TSM A320F

Failure of AFT Waste-Water Ice-Protection System


TASK 30-71-00-810-806-A
Failure of AFT Waste-Water Ice-Protection System


1. Possible Causes
  • CONTROL UNIT, WASTE WATER ICE PROTECTION- [15DU]
  • DRAINMAST "F" [14DU]
  • wiring
  • CONTROL UNIT (103DW)
  • SENSOR-TEMP, WASTE WTR [60DU]
  • HEATER 61DU
  • HEATER 62DU
  • microfuse
  • CONTROL UNIT 35DU
  • SENSOR-TEMP, WASTE WTR [70DU]
  • HEATER 71DU
  • HEATER 72DU
  • HEATER 73DU
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
SPRAY - COOLING
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 30-71-00-710-002
Operational Test of the Waste-Water Ice-Protection Heater-Elements
AMM 30-71-00-740-001
BITE Test of the Drainmast Ice Protection (through CIDS SYSTEM/TEST)
ASM 307101
AMM 30-71-17-000-001
Removal of the Waste-Water De-icing Sensor
AMM 30-71-17-400-001
Installation of the Waste-Water De-icing Sensor
AMM 30-71-18-000-001
Removal of Sensor
AMM 30-71-18-400-001
Installation of Sensor
AMM 30-71-19-000-001
Removal of Sensor
AMM 30-71-19-400-001
Installation of Sensor
AMM 30-71-34-000-001
Removal of the Waste-Water Ice-Protection Control-Unit
AMM 30-71-34-400-001
Installation of the Waste-Water Ice-Protection Control-Unit
AMM 30-71-51-000-001
Removal of the Drain Mast
AMM 30-71-51-400-001
Installation of the Drain Mast
AMM 30-71-53-000-001
Removal of the Waste-Water De-icing Heater Elements
AMM 30-71-53-400-001
Installation of the Waste-Water De-icing Heater Elements
AMM 30-71-57-000-001
Removal of the AFT Drain-Mast Pipe Heater-Elements
AMM 30-71-57-400-001
Installation of the AFT Drain-Mast Pipe Heater-Elements
AMM 30-71-58-000-001
Removal of AFT Waste-Pipe Heating Elements
AMM 30-71-58-400-001
Installation of AFT Waste-Pipe Heating Elements
AMM 30-73-00-740-001
BITE Test of the Potable Water Ice-Protection
AMM 30-73-34-000-001
Removal of the Potable and Waste Water Ice Protection Control Unit
AMM 30-73-34-400-001
Installation of the Potable and Waste Water Ice Protection Control Unit
3. Fault Confirmation
Subtask 30-71-00-710-060-A ** ON A/C NOT FOR ALL
A. Do the operational test of the waste-water ice-protection system AMM 30-71-00-710-002.
Subtask 30-71-00-710-060-B ** ON A/C NOT FOR ALL
A. Do the BITE Test of the Drainmast Ice Protection (via CIDS System/Test) AMM 30-71-00-740-001.
4. Fault Isolation
Subtask 30-71-00-810-059-A
A. If the green 'UNIT' LED of the CONTROL UNIT 15DU does not come on:
Replace the CONTROL UNIT, WASTE WATER ICE PROTECTION- [15DU] AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
Subtask 30-71-00-810-060-A
B. If the green 'HTR' LED of the CONTROL UNIT 15DU does not come on:
Do a check of the resistance value of the drainmast heater and temperature sensor. Refer to the related CMM for the correct values.
   (1) If the fault continues:
Replace the DRAINMAST "F" [14DU] AMM 30-71-51-000-001 and AMM 30-71-51-400-001.
     (a) If the fault continues:
Do a check and repair the wiring between:
  • CONTROL UNIT 15DU connector A/4 and DRAINMAST 14DU connector A/D
  • CONTROL UNIT 15DU connector A/5 and DRAINMAST 14DU connector A/E
  • CONTROL UNIT 15DU connector A/8 and DRAINMAST 14DU connector A/B
  • DRAINMAST 14DU connector A/C and GND
  • DRAINMAST 14DU connector A/A and GND ASM 307101.
Subtask 30-71-00-810-061-A
C. If the green 'UNIT' LED and the green 'HTR' LED of the CONTROL UNIT 15DU do not come on:
Do a check for the subsequent signals:
  • 115VAC at CONTROL UNIT 15DU connector A/14,
  • GND at CONTROL UNIT 15DU connector A/15 ASM 307101.
   (1) If the two signals are OK:
Replace the CONTROL UNIT, WASTE WATER ICE PROTECTION- [15DU] AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
   (2) If there is no 115 VAC:
Do a check and repair the wiring between CONTROL UNIT 15DU connector A/14 and CB 11DU ASM 307101.
   (3) If there is no GND:
Do a check and repair the wiring between CONTROL UNIT 15DU connector A/15 and GND ASM 307101.
Subtask 30-71-00-810-075-C ** ON A/C NOT FOR ALL
D. If the green 'UNIT' LED and the green 'HTR' LED of the CONTROL UNIT 5DU come on:
   (1) If the green I/II LED of the CONTROL UNIT 103DW does not come on:
  • do a check of the related microfuses.
     (a) If the microfuses are OK:
     (b) If the fault continues:
NOTE: Remove the insulation from around the SENSOR 60DU, the HEATER 61DU and the HEATER 62DU.
  • apply SPRAY - COOLING to the SENSOR 60DU for at least 10 s,
  • stop for approx. 120 s,
  • do a check of the temperature of the HEATER 61DU and HEATER 62DU.
       1 If the HEATER 61DU and HEATER 62DU stay cold:
       2 If the HEATER 61DU stays cold:
       3 If the HEATER 62DU stays cold:
     (c) If one microfuse is not OK:
  • do a check for a short circuit ASM 307101,
  • replace the microfuse .
Subtask 30-71-00-810-075-D ** ON A/C NOT FOR ALL
D. Fault of the CONTROL UNIT 35DU
   (1) If the green I/II LED of the CONTROL UNIT 35DU does not come on:
Do a check of the related microfuses.
     (a) If the microfuses are serviceable:
Replace the CONTROL UNIT 35DU AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
     (b) If the fault continues:
       1 Remove the insulation from around the SENSOR 60DU and the HEATERS 61DU and 62DU.
       2 Apply SPRAY - COOLING to the SENSOR 60DU for at least 10 s.
       3 Stop for approx. 120 s.
       4 Do a check of the temperature of the HEATERS 61DU and 62DU.
         a If the HEATERS 61DU and 62DU stay cold:
Replace the SENSOR-TEMP, WASTE WTR [60DU] AMM 30-71-19-000-001 and AMM 30-71-19-400-001.
         b If the HEATER 61DU stays cold:
Replace the HEATER 61DU AMM 30-71-57-000-001 and AMM 30-71-57-400-001.
         c If the HEATER 62DU stays cold:
Replace the HEATER 62DU AMM 30-71-57-000-001 and AMM 30-71-57-400-001.
     (c) If one microfuse is not serviceable:
       1 Do a check for a short circuit ASM 307101.
       2 Replace the microfuse .
   (2) If the green III/IV LED of the CONTROL UNIT 35DU does not come on:
Do a check of the related microfuses.
     (a) If the microfuses are serviceable:
Replace the CONTROL UNIT 35DU AMM 30-71-34-000-001 and AMM 30-71-34-400-001.
     (b) If the fault continues:
       1 Remove the insulation from around the SENSOR 70DU and the HEATERs 71DU, 72DU and 73DU.
       2 Apply SPRAY - COOLING to the SENSOR 70DU for at least 10 s.
       3 Stop for approx. 120 s.
       4 Do a check of the HEATERS 71DU, 72DU and 73DU.
         a If the HEATERs 71DU, 72DU and 73DU stay cold:
Replace the SENSOR-TEMP, WASTE WTR [70DU] AMM 30-71-18-000-001 and AMM 30-71-18-400-001.
         b If the HEATER 71DU stays cold:
Replace the HEATER 71DU AMM 30-71-58-000-001 and AMM 30-71-58-400-001.
         c If the HEATER 72DU stays cold:
Replace the HEATER 72DU AMM 30-71-58-000-001 and AMM 30-71-58-400-001.
         d If the HEATER 73DU stays cold:
Replace the HEATER 73DU AMM 30-71-58-000-001 and AMM 30-71-58-400-001.
     (c) If one microfuse is not serviceable:
       1 Do a check for a short circuit ASM 307101.
       2 Replace the microfuse .
Subtask 30-71-00-710-061-A
E. Do the test as given in Para. 3.A.
5. Close-up
Subtask 30-71-00-860-055-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:29:46 UTC