One or Both Wipers Running Continuously


TASK 30-45-00-810-811-A
One or Both Wipers Running Continuously


CAUTION: DO NOT OPERATE THE WIPERS WHEN THE WINDSHIELD IS DRY. PUT WATER ON THE WINDSHIELD WHEN THE WIPERS OPERATE.
1. Possible Causes
  • wiring
  • CTL SW-WIPER, CAPT [5DB1]
  • CTL SW-WIPER, F/O [5DB2]
  • MOTOR CONVERTER-WIPER, CAPT [6DB1]
  • MOTOR CONVERTER-WIPER, F/O [6DB2]
  • C/B-ANTI ICE/WIPER/CAPT [4DB1]
  • C/B-ANTI ICE/F/O/WIPER [4DB2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 24-00-00-810-803-A
Circuit Breaker Tripped and/or C/B TRIPPED Warning
AMM 30-45-00-720-001
Functional Test of the Windshield Rain Protection
ASM 304501
AMM 30-45-51-000-001
Removal of the Wiper Motor Converter
AMM 30-45-51-400-001
Installation of the Wiper Motor Converter
3. Fault Confirmation
Subtask 30-45-00-720-068-A
A. Test
Do the functional test of the windshield rain protection AMM 30-45-00-720-001.
4. Fault Isolation
Subtask 30-45-00-865-058-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VUANTI ICE/F/O/WIPER4DB2W12
122VUANTI ICE/WIPER/CAPT4DB1X12
Subtask 30-45-00-810-060-A
B. If the test confirms the fault:
  • Do a check of the status of the ANTI ICE/WIPER/CAPT (4DB1) (ANTI ICE/F/O/WIPER (4DB2)) circuit breaker.
   (1) If the ANTI ICE/WIPER/CAPT (4DB1) (ANTI ICE/F/O/WIPER (4DB2)) circuit breaker is closed:
  • Do a check for 28VDC at pin A of the MOTOR CONVERTER-WIPER, CAPT (6DB1) (MOTOR CONVERTER-WIPER, F/O (6DB2)) ASM 304501.
     (a) If there is no 28VDC:
  • Repair the wiring from pin 2 of the ANTI ICE/WIPER/CAPT (4DB1) (ANTI ICE/F/O/WIPER (4DB2)) circuit breaker to pin A of the MOTOR CONVERTER-WIPER, CAPT (6DB1) (MOTOR CONVERTER-WIPER, F/O (6DB2)).
     (b) If there is 28VDC:
       1 On the OVERHEAD CTL & IND panel 21VU (22VU), set the WIPER control switch to SLOW.
  • Do a check for ground at pin C of the MOTOR CONVERTER-WIPER, CAPT (6DB1) (MOTOR CONVERTER-WIPER, F/O (6DB2)).
         a If there is no ground signal:
  • Do a check of the wiring from pin C of the MOTOR CONVERTER-WIPER, CAPT (6DB1) (MOTOR CONVERTER-WIPER, F/O (6DB2)) to pin 3 of the WIPER control switch, CAPT (5DB1) (WIPER control switch, F/O (5DB2)).

    If there is no continuity:
  • Repair the above wiring .

    If there is continuity:
  • Replace the CTL SW-WIPER, CAPT [5DB1] ( CTL SW-WIPER, F/O [5DB2] )
         b If there is a ground signal:
  • Do the next step.
       2 On the OVERHEAD CTL & IND panel 21VU (22VU), set the WIPER control switch to FAST.
  • Do a check for ground at pin E of the MOTOR CONVERTER-WIPER, CAPT (6DB1) (MOTOR CONVERTER-WIPER (6DB2)).
         a If there is no ground signal:
  • Do a check of the wiring from pin E of the MOTOR CONVERTER-WIPER, CAPT (6DB1)(MOTOR CONVERTER-WIPER, F/O (6DB2)) to pin 4 of the WIPER control switch, CAPT (5DB1) (WIPER control switch, F/O (5DB2)).

    If there is no continuity:
  • Repair the above wiring .

    If there is continuity:
  • Replace the CTL SW-WIPER, CAPT [5DB1] ( CTL SW-WIPER, F/O [5DB2] ).
         b If there is a ground signal:
   (2) If the ANTI ICE/WIPER/CAPT (4DB1) (ANTI ICE/F/O/WIPER (4DB2)) circuit breaker is open:
     (a) If the fault continues:
  • Replace the C/B-ANTI ICE/WIPER/CAPT [4DB1] ( C/B-ANTI ICE/F/O/WIPER [4DB2] ).
   (3) If the fault continues: