W DOC AIRBUS | TSM A320F

Loss of the Identification of the Left or Right Side by the WHC 2


TASK 30-42-00-810-840-A
Loss of the Identification of the Left or Right Side by the WHC 2


1. Possible Causes
  • WHC-2 [2DG2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-42-34-000-001
Removal of the Window Heat Computer (WHC)
AMM 30-42-34-400-001
Installation of the Window Heat Computer (WHC)
3. Fault Confirmation
Subtask 30-42-00-710-113-A
A. Test
Not Applicable
4. Fault Isolation
Subtask 30-42-00-810-086-A
A. If the fault is identified by the maintenance message:
X WINDSHIELD SENSOR
   (1) Remove the WHC-2 [2DG2] AMM 30-42-34-000-001.
   (2) Do a check for 28VDC at pins C and S of the connector 2DG2-B on the wiring side at the same time.
     (a) If there is 28VDC at pins C and S at the same time:
  • there is an unwanted 28VDC at pin C
  • repair the wiring .
     (b) If there is no 28VDC at pins C and S at the same time:
[Rev.8 from Aug 2018] 2026.04.04 04:29:44 UTC