Loss of the GND/FLT Information


TASK 30-42-00-810-826-A
Loss of the GND/FLT Information


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-42-00-710-001
Operational Test of the Windshield Anti-Icing and Defogging
ASM 304202
AMM 30-42-34-000-001
Removal of the Window Heat Computer (WHC)
AMM 30-42-34-400-001
Installation of the Window Heat Computer (WHC)
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
3. Fault Confirmation
Subtask 30-42-00-710-100-A
A. Test
   (1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation
Subtask 30-42-00-810-075-A
A. If the test gives the maintenance message CHECK LGCIU - WHC 2 INTERFACE:
  • do a check for ground at pin B/F and/or pin B/T of the WHC 2 (2DG2).
   (1) If there is ground:
   (2) If there is no ground:
     (a) If the fault continues:
  • replace the LGCIU-2 [5GA2] .
     (b) If the fault continues:
       1 Do a check and repair the wiring :
  • from the WHC 2 (2DG2) pin B/F to the LGCIU 1 (5GA1) pin AB/14E and/or
  • from the WHC 2 (2DG2) pin B/T to the LGCIU 2 (5GA2) pin AB/14E.
ASM 304202
Subtask 30-42-00-710-101-A
B. Do the operational test given in Para. 3.