Loss of the Output Discretes (Side Window)
TASK 30-42-00-810-822-A
Loss of the Output Discretes (Side Window)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 30-42-00-710-092-A
Subtask 30-42-00-810-071-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:43 UTC
Loss of the Output Discretes (Side Window)
1. Possible Causes
- WHC-2 [2DG2]
wiring from the WHC 2 (2DG2) to the SDAC 1 (1WV1) wiring from the WHC 2 (2DG2) to the SDAC 2 (1WV2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-42-00-710-001 | Operational Test of the Windshield Anti-Icing and Defogging |
| ASM 304202 | |
| AMM 30-42-34-000-001 | Removal of the Window Heat Computer (WHC) |
| AMM 30-42-34-400-001 | Installation of the Window Heat Computer (WHC) |
Subtask 30-42-00-710-092-A
A. Test
(1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation(1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
Subtask 30-42-00-810-071-A
A. If the test gives the maintenance message CHECK SDAC-WINDOW WHC 2 INTERFACE:
Subtask 30-42-00-710-093-A - replace the WHC-2 [2DG2] , AMM 30-42-34-000-001 and AMM 30-42-34-400-001.
- do a check and repair the
wiring from the WHC 2 (2DG2) to the SDAC 1 (1WV1) pin B/E to pin AA/10J and/or - do a check and repair the
wiring from the WHC 2 (2DG2) to the SDAC 2 (1WV2) pin B/E to pin AA/10J ASM 304202.
B. Do the operational test given in Para. 3.