W DOC AIRBUS | TSM A320F

Loss of the Output Discretes (Windshield)


TASK 30-42-00-810-820-A
Loss of the Output Discretes (Windshield)


1. Possible Causes
  • WHC-2 [2DG2]
  • wiring from the WHC 2 (2DG2) to the SDAC 1 (1WV1)
  • wiring from the WHC 2 (2DG2) to the SDAC 2 (1WV2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-42-00-710-001
Operational Test of the Windshield Anti-Icing and Defogging
ASM 304202
AMM 30-42-34-000-001
Removal of the Window Heat Computer (WHC)
AMM 30-42-34-400-001
Installation of the Window Heat Computer (WHC)
3. Fault Confirmation
Subtask 30-42-00-710-088-A
A. Test
   (1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation
Subtask 30-42-00-810-069-A
A. If the test gives the maintenance message CHECK SDAC-WINDSHIELD WHC 2 INTERFACE:
   (1) If the fault continues:
  • do a check and repair the wiring from the WHC 2 (2DG2) to the SDAC 1 (1WV1) pin 3/D to pin AA/10H and/or
  • do a check and repair the wiring from the WHC 2 (2DG2) to the SDAC 2 (1WV2) pin B/D to pin AA/10H ASM 304202.
Subtask 30-42-00-710-089-A
B. Do the operational test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:43 UTC