Loss of the Heating System of the Right Sliding Window
TASK 30-42-00-810-816-A
Loss of the Heating System of the Right Sliding Window
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 30-42-00-710-080-A
Subtask 30-42-00-810-065-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:42 UTC
Loss of the Heating System of the Right Sliding Window
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-42-00-710-001 | Operational Test of the Windshield Anti-Icing and Defogging |
| ASM 304202 | |
| AMM 30-42-34-000-001 | Removal of the Window Heat Computer (WHC) |
| AMM 30-42-34-400-001 | Installation of the Window Heat Computer (WHC) |
| AMM 56-12-11-000-002 | Removal of the Sliding Window Panel |
| AMM 56-12-11-400-002 | Installation of the Sliding Window Panel |
Subtask 30-42-00-710-080-A
A. Test
(1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation(1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
Subtask 30-42-00-810-065-A
A. If the test gives the maintenance message R SLIDING WINDOW:
(a) Replace the WHC-2 [2DG2] , AMM 30-42-34-000-001 and AMM 30-42-34-400-001.
(b) If the fault continues:
Subtask 30-42-00-710-081-A - disconnect the connector from the R sliding window (8DG2) and do a check of the resistance between pin A and pin B.
NOTE: For right sliding window P/N NP165312 series,
For right sliding window P/N SPSA320 series 2 (with 2 sensors),
For right sliding window P/N SPSA320 series 3 (with 3 sensors),
For right sliding window P/N NH25216 series,
(1) If the resistance is not correct: For right sliding window P/N SPSA320 series 2 (with 2 sensors),
For right sliding window P/N SPSA320 series 3 (with 3 sensors),
For right sliding window P/N NH25216 series,
- replace the WINDOW-SLIDING, R [8DG2] , AMM 56-12-11-000-002 and AMM 56-12-11-400-002.
(a) Replace the WHC-2 [2DG2] , AMM 30-42-34-000-001 and AMM 30-42-34-400-001.
(b) If the fault continues:
- do a check and repair the
wiring from the WHC 2 (2DG2) to the R sliding window (8DG2) pin B/J to pin A/A ASM 304202.
B. Do the operational test given in Para. 3.
R Sliding Window Electrical Connector with 2 sensors