W DOC AIRBUS | TSM A320F

Loss of the Heating System of the Right Sliding Window


TASK 30-42-00-810-816-A
Loss of the Heating System of the Right Sliding Window


1. Possible Causes
  • WINDOW-SLIDING, R [8DG2]
  • WHC-2 [2DG2]
  • wiring from the WHC 2 (2DG2) to the R sliding window (8DG2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-42-00-710-001
Operational Test of the Windshield Anti-Icing and Defogging
ASM 304202
AMM 30-42-34-000-001
Removal of the Window Heat Computer (WHC)
AMM 30-42-34-400-001
Installation of the Window Heat Computer (WHC)
AMM 56-12-11-000-002
Removal of the Sliding Window Panel
AMM 56-12-11-400-002
Installation of the Sliding Window Panel
3. Fault Confirmation
Subtask 30-42-00-710-080-A
A. Test
   (1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation
Subtask 30-42-00-810-065-A
A. If the test gives the maintenance message R SLIDING WINDOW:
  • disconnect the connector from the R sliding window (8DG2) and do a check of the resistance between pin A and pin B.
   (1) If the resistance is not correct:
   (2) If the resistance is correct:
     (a) Replace the WHC-2 [2DG2] , AMM 30-42-34-000-001 and AMM 30-42-34-400-001.
     (b) If the fault continues:
  • do a check and repair the wiring from the WHC 2 (2DG2) to the R sliding window (8DG2) pin B/J to pin A/A ASM 304202.
Subtask 30-42-00-710-081-A
B. Do the operational test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:42 UTC