W DOC AIRBUS | TSM A320F

Loss of the Heating System of the Left Sliding Window


TASK 30-42-00-810-811-A
Loss of the Heating System of the Left Sliding Window


1. Possible Causes
  • WINDOW-SLIDING, L [8DG1]
  • WHC-1 [2DG1]
  • wiring from the WHC 1 (2DG1) to L sliding window (8DG1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-42-00-710-001
Operational Test of the Windshield Anti-Icing and Defogging
ASM 304201
AMM 30-42-34-000-001
Removal of the Window Heat Computer (WHC)
AMM 30-42-34-400-001
Installation of the Window Heat Computer (WHC)
AMM 56-12-11-000-002
Removal of the Sliding Window Panel
AMM 56-12-11-400-002
Installation of the Sliding Window Panel
3. Fault Confirmation
Subtask 30-42-00-710-070-A
A. Test
   (1) Do the operational test of the windshield anti-icing and defogging AMM 30-42-00-710-001.
4. Fault Isolation
Subtask 30-42-00-810-060-A
A. If the test gives maintenance message L SLIDING WINDOW:
  • Disconnect the electrical connector from the L sliding window (8DG1) and do a check of the resistance between pin A and pin B on the receptacle of the L sliding window (8DG1).
   (1) If the resistance is not correct:
   (2) If the resistance is correct:
     (a) Replace WHC-1 [2DG1] , AMM 30-42-34-000-001 and AMM 30-42-34-400-001.
     (b) If the fault continues:
  • Do a check and repair the wiring from the WHC 1 (2DG1) to L sliding window (8DG1) pin B/J to pin A/A ASM 304201.
Subtask 30-42-00-710-071-A
B. Do the operational test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:41 UTC