Wing Anti-Ice Control-Valves Stay Open After Ground Test
TASK 30-11-00-810-808-A
Wing Anti-Ice Control-Valves Stay Open After Ground Test
A. Referenced Information
3. Fault Confirmation
Subtask 30-11-00-710-055-A
(a) Do the operational test of the wing anti-ice system. AMM 30-11-00-710-001:
4. Fault Isolation
Subtask 30-11-00-810-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:30 UTC
Wing Anti-Ice Control-Valves Stay Open After Ground Test
WARNING:
DO NOT TOUCH THE ANTI-ICE DUCTS UNTIL THEY ARE COOL. THE TEMPERATURE OF THE DUCTS STAYS HIGH FOR SOME TIME AFTER THE ENGINE STOPS.
1. Possible Causes- RELAY-GROUND TEST [4DL]
- LGCIU-1 [5GA1]
- LGCIU-2 [5GA2]
- PROX SNSR-L L/G EXT, SYS 1 [21GA]
- PROX SNSR-R L/G EXT, SYS 2 [22GA]
- aircraft wiring
- RELAY-FAULT MONITOR C/O [6DL]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-11-00-710-001 | Operational Test of the Wing Ice-Protection System |
| ASM 301101 | |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 32-31-73-000-001 | Removal of the MLG Proximity-Sensors |
| AMM 32-31-73-400-001 | Installation of the MLG Proximity-Sensors |
| AMM 32-31-73-820-002 | Adjustment of the MLG Extension Proximity Sensors |
Subtask 30-11-00-710-055-A
CAUTION:
MAKE SURE THAT YOU SET THE WING ANTI-ICE SYSTEM P/BSW TO OFF AFTER 30 SECONDS. THIS WILL PREVENT DAMAGE TO THE SLATS.
A. Procedure NOTE: When the Wing Anti-Ice System Ground Test is OK, the system will automatically switch off after 30 seconds. If after 35 seconds the anti-ice symbols on the BLEED page, on the lower ECAM DU, do not go off, the ANTI ICE WING P/BSW must be released (out) manually.
(1) If the ECAM message WING A.-ICE OPEN ON GND is shown: (a) Do the operational test of the wing anti-ice system. AMM 30-11-00-710-001:
- if the test is OK, no more maintenance work is necessary
- if the test is not OK, do the fault isolation procedure in Para. 4.A.
Subtask 30-11-00-810-055-A
A. Procedure
(1) Replace the RELAY-GROUND TEST [4DL] .
(a) Do the test in Para. 3.A.:
(a) Do the test in Para 3.A.:
(a) Do the test in Para. 3.A.:
(a) Do the test in Para. 3.A.
(1) Replace the RELAY-GROUND TEST [4DL] .
(a) Do the test in Para. 3.A.:
- if the fault continues do the next step.
NOTE: When the Anti-Ice Ground Test is done two or more times, keep sufficient time between each test, to let the slats become cool.
(2) Remove the RELAY-GROUND TEST 4DL and RELAY-FAULT MONITOR C/O 6DL from their holders. NOTE: When the RELAY-GROUND TEST 4DL is removed from its holder, this will remove the ground from pin Z of the RELAY-FAULT MONITOR C/O 6DL.
(3) At pin Z of the Relay 6DL holder, do a check for continuity to ground: - if there is no ground, do step (10)
- if there is a ground, do the next step.
- if the ground on pin Z stays when both the LGCIUs have been removed, do step (9)
- if the ground on pin Z goes when an LGCIU is removed, do the next step.
- if the ground on pin Z goes when the LGCIU is removed from the same system as in step (4), install the LGCIUs and relays 4DL and 6DL, and do step (7)
- if the ground on pin Z goes when the LGCIU is removed from the opposite system to that in step (4), install the LGCIUs and relays 4DL and 6DL, and do the next step.
(a) Do the test in Para 3.A.:
- if the fault continues, do the next step.
- for LGCIU1 adjust proximity sensor 21GA
- for LGCIU2 adjust proximity sensor 22GA.
- if the fault continues, do the next step.
(a) Do the test in Para. 3.A.:
- if the fault continues, do the next step.
- the RELAY-GROUND TEST 4DL
- the RELAY-ANTI ICE VALVE CONTROL 5DL
- the LGCIU1 5GA1
- the LGCIU2 5GA2
- if the fault continues, do the next step.
(a) Do the test in Para. 3.A.