Wing Anti-Ice Class 3 Faults
TASK 30-11-00-810-805-A
Wing Anti-Ice Class 3 Faults
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 30-11-00-710-054-A
Subtask 30-11-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:30 UTC
Wing Anti-Ice Class 3 Faults
1. Possible Causes
- Wing Anti-Ice System
- Wing Anti-Ice Control Valve Filter.
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 30-11-00-710-001 | Operational Test of the Wing Ice-Protection System |
| AMM 30-11-51-000-002 | Removal of the Anti-Ice Valve Filter |
| AMM 30-11-51-400-002 | Installation of the Anti-Ice Valve Filter |
Subtask 30-11-00-710-054-A
A. Procedure
(1) Examine the ECAM for the Wing Anti-Ice System fault warning.
4. Fault Isolation(1) Examine the ECAM for the Wing Anti-Ice System fault warning.
Subtask 30-11-00-810-054-A
A. Procedure
(1) If the ECAM shows no Wing Anti-Ice System warning, the CFDS message is spurious, and no maintenance steps are necessary.
(2) If the ECAM shows the Wing Anti-Ice System warning:
(a) Clean or replace the applicable Wing Anti-Ice Control Valve Filter. , AMM 30-11-51-000-002 and AMM 30-11-51-400-002
(b) Do the operational test of the wing anti-ice system, AMM 30-11-00-710-001.
(3) If the fault continues:
(a) Do the trouble shooting procedure related to the maintenance message.
(1) If the ECAM shows no Wing Anti-Ice System warning, the CFDS message is spurious, and no maintenance steps are necessary.
(2) If the ECAM shows the Wing Anti-Ice System warning:
(a) Clean or replace the applicable Wing Anti-Ice Control Valve Filter. , AMM 30-11-51-000-002 and AMM 30-11-51-400-002
(b) Do the operational test of the wing anti-ice system, AMM 30-11-00-710-001.
(3) If the fault continues:
(a) Do the trouble shooting procedure related to the maintenance message.