Wing Anti-Ice Class 3 Faults


TASK 30-11-00-810-805-A
Wing Anti-Ice Class 3 Faults


1. Possible Causes
  • Wing Anti-Ice System
  • Wing Anti-Ice Control Valve Filter.
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 30-11-00-710-001
Operational Test of the Wing Ice-Protection System
AMM 30-11-51-000-002
Removal of the Anti-Ice Valve Filter
AMM 30-11-51-400-002
Installation of the Anti-Ice Valve Filter
3. Fault Confirmation
Subtask 30-11-00-710-054-A
A. Procedure
   (1) Examine the ECAM for the Wing Anti-Ice System fault warning.
4. Fault Isolation
Subtask 30-11-00-810-054-A
A. Procedure
   (1) If the ECAM shows no Wing Anti-Ice System warning, the CFDS message is spurious, and no maintenance steps are necessary.
   (2) If the ECAM shows the Wing Anti-Ice System warning:
     (a) Clean or replace the applicable Wing Anti-Ice Control Valve Filter. , AMM 30-11-51-000-002 and AMM 30-11-51-400-002
     (b) Do the operational test of the wing anti-ice system, AMM 30-11-00-710-001.
   (3) If the fault continues:
     (a) Do the trouble shooting procedure related to the maintenance message.