Wing Anti-Ice Control-Valve Failed Open


TASK 30-11-00-810-801-A
Wing Anti-Ice Control-Valve Failed Open


WARNING: DO NOT TOUCH THE ANTI-ICE DUCTS UNTIL THEY ARE COOL. THE TEMPERATURE OF THE DUCTS STAYS HIGH FOR SOME TIME AFTER THE ENGINE STOPS.
1. Possible Causes
  • VALVE-WING ANTI ICE CONTROL, L [9DL]
  • VALVE-WING ANTI ICE CONTROL, R [10DL]
  • RELAY-ANTI ICE VALVE CONTROL 5DL
  • aircraft wiring
  • ZONE CONTROLLER [8HK]
  • CONT-AIR COND SYSTEM 2 [57HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 204650
ESPM 205200
ESPM 205300
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
ASM 216301
AMM 21-63-34-000-001
Removal of the Zone Controller
AMM 21-63-34-400-001
Installation of the Zone Controller
AMM 30-11-00-710-001
Operational Test of the Wing Ice-Protection System
ASM 301101
AMM 30-11-51-000-001
Removal of the Wing Anti-Ice Control Valve
AMM 30-11-51-400-001
Installation of the Wing Anti-Ice Control Valve
3. Fault Confirmation
Subtask 30-11-00-710-050-A
A. Procedure
   (1) With no electrical power or bleed air supplied to the wing anti-ice system:
     (a) Examine the identified defective Valve-Wing Anti Ice Control L(R) 9DL(10DL).
4. Fault Isolation
Subtask 30-11-00-810-050-A ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) If the locking lever position on the Wing Anti-Ice (WAI) valve 9DL(10DL) shows that the valve is open:
NOTE: A serviceable WAI valve will not open if:
  • There is no bleed air supply
  • The electrical circuits are de-energized.
     (a) Replace the applicable VALVE-WING ANTI ICE CONTROL, L [9DL] or VALVE-WING ANTI ICE CONTROL, R [10DL] , AMM 30-11-51-000-001 and AMM 30-11-51-400-001.
   (2) If the WAI valve 9DL(10DL) is closed in Para. 3.A.(1):
     (a) Supply bleed air to the WAI system AMM 30-11-00-710-001, but do not set the P/BSW-Anti-Ice Wing (3DL) to on.
NOTE: This makes sure that the WAI valve has not opened with:
  • Bleed air supplied
  • The electrical circuits de-energized.
     (b) Examine the locking lever position on the WAI valve 9DL(10DL):
       1 If the locking lever position shows the WAI valve is open:
  • Do a check for 28VDC at the WAI valve connector A pin A
    ASM 301101:
         a If there is no 28VDC:
         b If there is 28VDC:
       2 If the locking lever position shows the WAI valve is closed:
NOTE: The WAI valve automatically moves to the closed position when the electrical circuits are de-energized.
         a Do the operational test of the wing anti-ice system AMM 30-11-00-710-001:
  • If the test shows a fault, do the trouble shooting related to the maintenance message.
     (c) Stop the bleed air supply AMM 30-11-00-710-001.
   (3) If the fault continues:
     (a) Do a check of the aircraft wiring between the WAI valve 9DL(10DL) and the Relay Anti-Ice Valve Control (5DL)
ASM 301101
ESPM 205200.
     (b) Repair all the unserviceable wiring and connectors ESPM 205300.
     (c) Do the operational test of the WAI system AMM 30-11-00-710-001.
   (4) If no faults are found in the WAI system:
     (a) Do a check of the aircraft wiring between the applicable wing anti-ice control-valve (9DL) or (10DL), connector A pin J and the SDAC ATA 31-54
ASM 301101
ESPM 205200.
     (b) Repair all the unserviceable wiring and connectors ESPM 205300.
     (c) Do the operational test of the wing anti-ice system AMM 30-11-00-710-001.
   (5) If the fault continues:
     (a) Replace the ZONE CONTROLLER [8HK] , AMM 21-63-34-000-001 and AMM 21-63-34-400-001.
     (b) Do the operational test of the wing anti-ice system AMM 30-11-00-710-001.
   (6) If the fault continues:
     (a) Do a check of the aircraft wiring between the VALVE-WING ANTI ICE CONTROL, L [9DL] or VALVE-WING ANTI ICE CONTROL, R [10DL] and ZONE CONTROLLER [8HK]
ASM 301101
ESPM 205200.
     (b) Repair all the unserviceable wiring and connectors ESPM 205300.
     (c) Do the operational test of the wing anti-ice system AMM 30-11-00-710-001.
Subtask 30-11-00-810-050-B ** ON A/C NOT FOR ALL
A. If there is confirmation of the fault:
   (1) If the locking lever position on the Wing Anti-Ice (WAI) valve 9DL(10DL) shows that the valve is open:
NOTE: A serviceable WAI valve will not open if:
  • There is no bleed air supply
  • The electrical circuits are de-energized.
     (a) Replace the applicable VALVE-WING ANTI ICE CONTROL, L [9DL] or VALVE-WING ANTI ICE CONTROL, R [10DL] , AMM 30-11-51-000-001 and AMM 30-11-51-400-001.
   (2) If the WAI valve 9DL(10DL) is closed in Para. 3.A.(1):
     (a) Supply bleed air to the WAI system AMM 30-11-00-710-001, but do not set the P/BSW-Anti-Ice Wing (3DL) to on.
NOTE: This makes sure that the WAI valve has not opened with:
  • Bleed air supplied
  • The electrical circuits de-energized.
     (b) Examine the locking lever position on the WAI valve 9DL(10DL):
       1 If the locking lever position shows the WAI valve is open:
  • Do a check for 28VDC at the WAI valve connector A pin A
    ASM 301101:
         a If there is no 28VDC:
         b If there is 28VDC:
       2 If the locking lever position shows the WAI valve is closed:
NOTE: The WAI valve automatically moves to the closed position when the electrical circuits are de-energized.
         a Do the operational test of the wing anti-ice system AMM 30-11-00-710-001:
  • If the test shows a fault, do the trouble shooting related to the maintenance message.
     (c) Stop the bleed air supply AMM 30-11-00-710-001.
   (3) If the fault continues:
     (a) Do a check of the aircraft wiring between the WAI valve 9DL(10DL) and the Relay Anti-Ice Valve Control (5DL)
ASM 301101
ESPM 205200.
     (b) Repair all the unserviceable wiring and connectors ESPM 205300.
     (c) Do the operational test of the WAI system AMM 30-11-00-710-001.
   (4) If no faults are found in the WAI system:
     (a) Do a check of the aircraft wiring between the applicable wing anti-ice control-valve (9DL) or (10DL), connector A pin J and the SDAC ATA 31-54
ASM 301101
ESPM 205200.
     (b) Repair all the unserviceable wiring and connectors ESPM 205300.
     (c) Do the operational test of the wing anti-ice system AMM 30-11-00-710-001.
   (5) If the fault continues:
     (a) Replace the CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
     (b) Do the operational test of the wing anti-ice system AMM 30-11-00-710-001.
   (6) If the fault continues:
     (a) Do a check of the aircraft wiring between the VALVE-WING ANTI ICE CONTROL, L [9DL] or VALVE-WING ANTI ICE CONTROL, R [10DL] and CONT-AIR COND SYSTEM 2 [57HH]
ASM 216301
ESPM 205200.
     (b) Repair all the unserviceable wiring and connectors ESPM 205300.
     (c) Do the operational test of the wing anti-ice system AMM 30-11-00-710-001.
[Rev.8 from Aug 2018] 2026.04.04 04:29:30 UTC