Overheat Indication of the Yellow Electric Pump
TASK 29-24-00-810-802-A
Overheat Indication of the Yellow Electric Pump
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-24-00-710-052-A
Subtask 29-24-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:30 UTC
Overheat Indication of the Yellow Electric Pump
1. Possible Causes
- wiring
- PACKAGE E-PUMP [3075GX]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-24-00-710-001 | Operational Test of the Yellow Auxiliary Power |
| ASM 292401 | |
| AMM 29-24-51-000-001 | Removal of the Electric Pump |
| AMM 29-24-51-400-001 | Installation of the Electric Pump |
Subtask 29-24-00-710-052-A
A. Do the operational test of the electric pump of the Yellow hydraulic system AMM 29-24-00-710-001.
4. Fault IsolationSubtask 29-24-00-810-051-A
A. If the test gives the message HYD Y ELEC PUMP OVHT:
Subtask 29-24-00-710-053-A - disconnect the electrical connector (3075GX-A) and look at the upper ECAM DU.
- do a check of the wiring between:
the PACKAGE E-PUMP [3075GX] connector A/F and the SDAC and repair as necessary ASM 292401.
- replace the PACKAGE E-PUMP [3075GX] AMM 29-24-51-000-001 and AMM 29-24-51-400-001.
B. Do the test as given in Para. 3. A. to make sure that the operation is correct.