W DOC AIRBUS | TSM A320F

Low Pressure of the Power Transfer Unit (PTU) (Green to Yellow)


TASK 29-23-00-810-811-A
Low Pressure of the Power Transfer Unit (PTU) (Green to Yellow)


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-00-00-280-004
Check of the Internal Leakage of the Power Transfer Unit (PTU)
AMM 29-10-00-220-001
Functional Check to Monitor Internal Leak Rate of Yellow and Green Hydraulic Systems
AMM 29-11-15-000-001
Removal of the Power Transfer Unit (PTU) Manifold of the Green Hydraulic System
AMM 29-11-15-400-001
Installation of the Power Transfer Unit (PTU) Manifold of the Green Hydraulic System
AMM 29-13-14-000-001
Removal of the HP Manifold of the Yellow Hydraulic System
AMM 29-13-14-400-001
Installation of the HP Manifold of the Yellow Hydraulic System
AMM 29-13-15-000-001
Removal of the Power Transfer Unit (PTU) Manifold of the Yellow Hydraulic System
AMM 29-13-15-400-001
Installation of the Power Transfer Unit (PTU) Manifold of the Yellow Hydraulic System
AMM 29-13-32-000-001
Removal of the Pressure Relief Valve of the Yellow Hydraulic System
AMM 29-13-32-400-001
Installation of the Pressure Relief Valve of the Yellow Hydraulic System
AMM 29-13-36-000-001
Removal of the Engine 2 Yellow Hydraulic Pump Delivery Check Valve
AMM 29-13-36-400-001
Installation of the Engine 2 Yellow Hydraulic Pump Delivery Check Valve
AMM 29-23-00-710-003
Functional Check of the Power Transfer Unit (PTU) Yellow to Green
AMM 29-23-41-000-001
Removal of the Green/Yellow Power Transfer Unit
AMM 29-23-41-400-001
Installation of the Green/Yellow Power Transfer Unit
3. Fault Confirmation
Subtask 29-23-00-710-069-A
A. Do these tests:
   (1) Do a check of the internal leakage of the Power Transfer Unit (PTU) AMM 29-00-00-280-004.
   (2) If the internal leakage of the PTU is in the permitted limits:
  • do a functional check to monitor the internal leak rate of the Yellow and Green hydraulic systems AMM 29-10-00-220-001.
   (3) If the internal leak rate of the Yellow and Green hydraulic systems is in the permitted limits:
  • do the operational test of the PTU AMM 29-23-00-710-003.
  • look for external leakage of the Yellow hydraulic system.
4. Fault Isolation
Subtask 29-23-00-810-063-A
A. If there is no external leakage and the pressure in the Yellow hydraulic system was less than 2100 psi during the operational test of the PTU:
- Replace the PTU [1088GM] AMM 29-23-41-000-001 and AMM 29-23-41-400-001.
   (1) If the fault continues:
   (2) If the fault continues:
   (3) If the fault continues:
     (a) Do the test given in the Para. Fault Confirmation.
   (4) If the fault continues:
     (a) Replace the RELIEF VALVE Y SYS [3063GM] , AMM 29-13-32-000-001 and AMM 29-13-32-400-001.
     (b) Do the test in the Para. Fault confirmation.
   (5) If the fault continues:
     (a) Replace the MANIFOLD HP (3014GM), AMM 29-13-14-000-001 and AMM 29-13-14-400-001.
Subtask 29-23-00-710-070-A
B. Do the test as given in para. 3. to make sure that the operation is correct.
[Rev.8 from Aug 2018] 2026.04.04 04:39:57 UTC