Low Pressure of the Power Transfer Unit (PTU) (Green to Yellow)
TASK 29-23-00-810-811-A
Low Pressure of the Power Transfer Unit (PTU) (Green to Yellow)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-23-00-710-069-A
Subtask 29-23-00-810-063-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:29 UTC
Low Pressure of the Power Transfer Unit (PTU) (Green to Yellow)
1. Possible Causes
- PTU [1088GM]
- MANIFOLD,PTU [3015GM]
- MANIFOLD,PTU [1113GM]
- CHECK VALVE-ENG 2 PUMP DELIVERY, Y [3050GM]
- RELIEF VALVE Y SYS [3063GM]
MANIFOLD HP (3014GM)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-00-00-280-004 | Check of the Internal Leakage of the Power Transfer Unit (PTU) |
| AMM 29-10-00-220-001 | Functional Check to Monitor Internal Leak Rate of Yellow and Green Hydraulic Systems |
| AMM 29-11-15-000-001 | Removal of the Power Transfer Unit (PTU) Manifold of the Green Hydraulic System |
| AMM 29-11-15-400-001 | Installation of the Power Transfer Unit (PTU) Manifold of the Green Hydraulic System |
| AMM 29-13-14-000-001 | Removal of the HP Manifold of the Yellow Hydraulic System |
| AMM 29-13-14-400-001 | Installation of the HP Manifold of the Yellow Hydraulic System |
| AMM 29-13-15-000-001 | Removal of the Power Transfer Unit (PTU) Manifold of the Yellow Hydraulic System |
| AMM 29-13-15-400-001 | Installation of the Power Transfer Unit (PTU) Manifold of the Yellow Hydraulic System |
| AMM 29-13-32-000-001 | Removal of the Pressure Relief Valve of the Yellow Hydraulic System |
| AMM 29-13-32-400-001 | Installation of the Pressure Relief Valve of the Yellow Hydraulic System |
| AMM 29-13-36-000-001 | Removal of the Engine 2 Yellow Hydraulic Pump Delivery Check Valve |
| AMM 29-13-36-400-001 | Installation of the Engine 2 Yellow Hydraulic Pump Delivery Check Valve |
| AMM 29-23-00-710-003 | Functional Check of the Power Transfer Unit (PTU) Yellow to Green |
| AMM 29-23-41-000-001 | Removal of the Green/Yellow Power Transfer Unit |
| AMM 29-23-41-400-001 | Installation of the Green/Yellow Power Transfer Unit |
Subtask 29-23-00-710-069-A
A. Do these tests:
(1) Do a check of the internal leakage of the Power Transfer Unit (PTU) AMM 29-00-00-280-004.
(2) If the internal leakage of the PTU is in the permitted limits:
4. Fault Isolation(1) Do a check of the internal leakage of the Power Transfer Unit (PTU) AMM 29-00-00-280-004.
(2) If the internal leakage of the PTU is in the permitted limits:
- do a functional check to monitor the internal leak rate of the Yellow and Green hydraulic systems AMM 29-10-00-220-001.
- do the operational test of the PTU AMM 29-23-00-710-003.
- look for external leakage of the Yellow hydraulic system.
Subtask 29-23-00-810-063-A
A. If there is no external leakage and the pressure in the Yellow hydraulic system was less than 2100 psi during the operational test of the PTU:
- Replace the PTU [1088GM] AMM 29-23-41-000-001 and AMM 29-23-41-400-001.
(1) If the fault continues:
(4) If the fault continues:
(a) Replace the RELIEF VALVE Y SYS [3063GM] , AMM 29-13-32-000-001 and AMM 29-13-32-400-001.
(b) Do the test in the Para. Fault confirmation.
(5) If the fault continues:
(a) Replace theMANIFOLD HP (3014GM) , AMM 29-13-14-000-001 and AMM 29-13-14-400-001.
Subtask 29-23-00-710-070-A - Replace the PTU [1088GM] AMM 29-23-41-000-001 and AMM 29-23-41-400-001.
(1) If the fault continues:
- Replace the MANIFOLD,PTU [3015GM] AMM 29-13-15-000-001 and AMM 29-13-15-400-001.
- Replace the MANIFOLD,PTU [1113GM] AMM 29-11-15-000-001 and AMM 29-11-15-400-001.
- Replace the CHECK VALVE-ENG 2 PUMP DELIVERY, Y [3050GM] AMM 29-13-36-000-001 and AMM 29-13-36-400-001.
(4) If the fault continues:
(a) Replace the RELIEF VALVE Y SYS [3063GM] , AMM 29-13-32-000-001 and AMM 29-13-32-400-001.
(b) Do the test in the Para. Fault confirmation.
(5) If the fault continues:
(a) Replace the
B. Do the test as given in para. 3. to make sure that the operation is correct.