TASK 29-23-00-810-810-A
Missing PTU-arrow on the ECAM


1. Possible Causes
  • DU-ECAM, UPPER [4WT1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-23-00-710-002
Functional Check of the Power Transfer Unit (PTU) Green to Yellow
AMM 29-23-00-710-003
Functional Check of the Power Transfer Unit (PTU) Yellow to Green
AMM 31-60-00-710-002
Operational Test of EFIS/ECAM Switching Functions
AMM 31-60-00-710-005
Operational Check of Correct Operation of EFIS and ECAM DMC Automatic and Manual Transfer
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
3. Fault Confirmation
Subtask 29-23-00-710-067-A
A. Do these tests:
   (1) Do the operational check of the PTU GREEN to YELLOW AMM 29-23-00-710-002.
   (2) Do the operational check of the PTU YELLOW to GREEN AMM 29-23-00-710-003.
4. Fault Isolation
Subtask 29-23-00-810-062-A ** ON A/C NOT FOR ALL
A. If the Test gives no indication of the PTU arrow on the System Page on the DU-ECAM, UPPER [4WT1] :
   (1) Do the operational test of the EFIS/ECAM switching functions AMM 31-60-00-710-002.
     (a) If the PTU arrow comes into view during this test on an different ECAM Display Unit:
Subtask 29-23-00-810-062-B ** ON A/C NOT FOR ALL
A. If the test gives no indication of the PTU arrow on the system page on the DU-ECAM, UPPER [4WT1] :
   (1) Do the operational test of EFIS/ECAM automatic and manual transfer AMM 31-60-00-710-005.
     (a) If the PTU arrow comes into view during this test on a different ECAM Display Unit:
Subtask 29-23-00-710-068-A
B. Do the test as given in para. 3. to make sure that the indication is correct.