Ram Air Turbine does not retract
TASK 29-22-00-810-803-A
Ram Air Turbine does not retract
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-22-00-865-054-A
Subtask 29-22-00-810-053-B
Subtask 29-22-00-860-058-B
[Rev.8 from Aug 2018]
2026.04.04 04:29:28 UTC
Ram Air Turbine does not retract
1. Possible Causes
- RAT interlock proximity switch
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 29-22-00-820-005 | Adjustment of the RAT Interlock Proximity Switch |
| AMM 29-22-00-869-006 | Retraction of the Ram Air Turbine (RAT) on the Ground |
| AMM 29-22-51-000-011 | Removal of the RAT Interlock Proximity Switch |
| AMM 29-22-51-400-011 | Installation of the RAT Interlock Proximity Switch |
Subtask 29-22-00-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-22-00-860-056-B | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | D14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | HYD/RAT/CTL | 2801GE | B13 |
| ** ON A/C ALL | |||
| 106VU | CSM/G /EV/MAN/SPLY | 6XE | B04 |
| 121VU | HYDRAULIC/RAT/SPLY/EXTN/SOL1 | 2803GE | P33 |
B. Aircraft Maintenance Configuration
(1) Open the access panel 197EB.
(2) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(3) On the RAT ground control-panel (3GE):
(5) During the retraction of the RAT:
4. Fault Isolation(1) Open the access panel 197EB.
(2) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(3) On the RAT ground control-panel (3GE):
- Set the 28VDC switch to the ON position.
- Set the LAMP TEST switch to the test position and make sure that all lights come on.
(5) During the retraction of the RAT:
- Obey the interlock warning light in the RAT control panel (3GE).
- Obey the operation of the RAT.
Subtask 29-22-00-810-053-B
A. If the RAT starts to retract but returns to its fully extended position and the interlock warning light on the RAT control panel (3GE) comes on:
Subtask 29-22-00-860-057-B ** ON A/C NOT FOR ALL - Do the adjustment of the RAT interlock proximity switch AMM 29-22-00-820-005.
- Replace the RAT interlock proximity switch AMM 29-22-51-000-011 and AMM 29-22-51-400-011.
B. Do the fault confirmation procedure as given in Para. 3. to make sure that the operation is correct.
5. Close-upSubtask 29-22-00-860-058-B
A. Put the aircraft back to the serviceable condition.
(1) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(2) Close the access panel 197EB.
(1) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
(2) Close the access panel 197EB.