Yellow Hydraulic System Low Pressure/Overheat Caused by User System Fault


TASK 29-13-00-810-819-A
Yellow Hydraulic System Low Pressure/Overheat Caused by User System Fault


1. Possible Causes
  • user system component internal leak
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 29-13-00-810-802-A
Overheat Indication of the Yellow Hydraulic System
TSM TASK 29-13-00-810-805-A
Loss of the System Pressure of the Yellow Hydraulic System
3. Fault Confirmation
Subtask 29-13-00-700-050-A
A. Test
   (1) If there are overheat and or low pressure indications:
     (a) Do the Fault Isolation.
NOTE: A low pressure or overheat indication can be caused by a user system component internal leak .
4. Fault Isolation
Subtask 29-13-00-810-075-A
A. Procedure
   (1) Make sure that all the user systems of the Yellow HYD system that follow have no defects:
  • LH and RH Spoilers 4
  • LH and RH Spoilers 2
  • RH Elevator
  • THS
  • LH Flaps Wing Tip Brake
  • Rudder
  • Yaw Damper
  • Reverse Eng 2
  • Cargo Doors
  • Alternate Brakes
  • Flaps.
   (2) If all the user systems are serviceable:
     (a) Do the procedures for the Yellow HYD system Low Pressure and Overheat, (Ref. TSM TASK 29-13-00-810-805) and (Ref. TSM TASK 29-13-00-810-802).
   (3) If the aircraft is on a remote site and the necessary metering equipment is not available, do the procedures as far as possible:
     (a) Examine the user system components for unusual increase in noise and temperature.
     (b) Replace a system component that shows an unusual increase in noise and temperature.
   (4) Do the applicable test in Para. 3. A. of (Ref. TSM TASK 29-13-00-810-802) and (Ref. TSM TASK 29-13-00-810-805).
5. Close-up
Subtask 29-13-00-942-050-A
A. Put the aircraft back to the serviceable condition.