W DOC AIRBUS | TSM A320F

Fault of the System Pressure Indication of the Yellow Hydraulic System


TASK 29-13-00-810-816-A
Fault of the System Pressure Indication of the Yellow Hydraulic System


1. Possible Causes
  • TIME RELAY [3816GX]
  • RELAY-TIME [6MJ]
  • SYSTEM-PRESS-SW [3151GN]
  • RELAY-SCCB PWR SPLY [3811GX]
  • wiring
  • terminal block 1862VT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2046100
AMM 22-91-00-710-001
Ground Scanning of the AFS
AMM 29-13-00-710-002
Operational Test of the Yellow Hydraulic System
AWM 293201
AMM 29-32-12-000-003
Removal of the System Pressure Switch
AMM 29-32-12-400-003
Installation of the System Pressure Switch
3. Fault Confirmation
Subtask 29-13-00-710-067-A
A. Do the operational test of the Yellow hydraulic system AMM 29-13-00-710-002.
4. Fault Isolation
Subtask 29-13-00-810-070-A
A. If the test gives:
  • The message HYD Y SYS LO PR on the upper ECAM DU.
  • A system pressure indication of 3000 psi on the lower ECAM DU.
  • An intermittent PTU indication in amber on the lower ECAM DU.
Do the ground scanning of the AFS AMM 22-91-00-710-001.
   (1) If the ground scanning shows the messages:
  • AFS: HYD 3151GN
  • AFS: ELAC
  • SFCC 2: WRONG INHIBIT SIGN FROM CARGO DOOR YELLOW SYSTEM
     (a) Replace TIME RELAY [3816GX] .
   (2) If the fault continues:
  • Replace RELAY-TIME [6MJ] .
   (3) If the fault continues:
   (4) If the fault continues:
   (5) If the fault continues:
     (a) Do a check of the wiring between:
Subtask 29-13-00-710-068-A
B. Do the fault confirmation procedure as given in Para. 3. to make sure that the operation is correct.
[Rev.8 from Aug 2018] 2026.04.04 04:29:27 UTC