FAULT Light of the YELLOW ENG 2 PUMP P/BSW is ON
TASK 29-13-00-810-812-A
FAULT Light of the YELLOW ENG 2 PUMP P/BSW is ON
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-13-00-860-059-A
Subtask 29-13-00-810-063-A
Subtask 29-13-00-860-060-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:26 UTC
FAULT Light of the YELLOW ENG 2 PUMP P/BSW is ON
1. Possible Causes
- BOARD-ANN LT TEST & INTFC [20LP]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| AMM 33-14-00-710-001 | Operational Test of the Lights |
| ASM 331422 | |
| AMM 33-14-33-000-001 | Removal of the Annunciator-Light Test and Interface-Board |
| AMM 33-14-33-400-001 | Installation of the Annunciator-Light Test and Interface-Board |
Subtask 29-13-00-860-059-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) On the overhead panel 40VU, look for the FAULT light of the YELLOW/ENG 2 PUMP P/BSW.
4. Fault Isolation(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) On the overhead panel 40VU, look for the FAULT light of the YELLOW/ENG 2 PUMP P/BSW.
Subtask 29-13-00-810-063-A
A. If the Fault Confirmation gives:
Subtask 29-13-00-710-065-A - the YELLOW/ENG 2 PUMP P/BSW FAULT on panel 40VU:
- replace the BOARD-ANN LT TEST & INTFC [20LP] AMM 33-14-33-000-001 and AMM 33-14-33-400-001.
- do a check and repair the wiring between the:
BOARD-ANN LT TEST & INTFC (20LP) pin A/10 and the P/BSW-HYD/YELLOW/ENG 2 PUMP (3703GD) pin A/7 ASM 331422.
B. Do the operational test of the annunciator light test system AMM 33-14-00-710-001 to make sure that the operation is correct.
5. Close-upSubtask 29-13-00-860-060-A