Fault of the System Pressure Indication of the Yellow Hydraulic System on the ECAM Lower DU
TASK 29-13-00-810-809-A
Fault of the System Pressure Indication of the Yellow Hydraulic System on the ECAM Lower DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 29-13-00-710-061-A
Subtask 29-13-00-810-060-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:26 UTC
Fault of the System Pressure Indication of the Yellow Hydraulic System on the ECAM Lower DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-24-00-863-001 | Pressurize the Yellow Hydraulic System with the Electric Pump |
| AMM 29-24-00-864-001 | Depressurize the Yellow Hydraulic System |
| AMM 29-24-55-000-001 | Removal of the Contactor - Yellow Electric Pump Supply |
| AMM 29-24-55-400-001 | Installation of the Contactor - Yellow Electric Pump Supply |
| AMM 29-32-11-000-003 | Removal of the Hydraulic Pressure Transducer |
| AMM 29-32-11-400-003 | Installation of the Hydraulic Pressure Transducer |
Subtask 29-13-00-710-061-A
A. Test
(2) Operate the rudder pedals.
(3) Make sure that the rudder operates.
(4) De-pressurize the Yellow hydraulic System AMM 29-24-00-864-001.
4. Fault IsolationWARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
(1) Pressurize the Yellow hydraulic system with the E-pump AMM 29-24-00-863-001. (2) Operate the rudder pedals.
(3) Make sure that the rudder operates.
(4) De-pressurize the Yellow hydraulic System AMM 29-24-00-864-001.
Subtask 29-13-00-810-060-A
A. If, during the test, the operation of the rudder is correct, but the HYD page on the ECAM lower DU shows for the Yellow hydraulic system the subsequent condition:
Subtask 29-13-00-710-062-A - the system pressure indication in amber (less than 1450 PSI),
- the system pressure identification (YELLOW) in white,
- the system arrow in green,
replace the HYDR. PRESSURE TRANSMITTER [3065GN] AMM 29-32-11-000-003 and AMM 29-32-11-400-003. - The system arrow in white,
replace the contactor yellow electrical pump supply CONTACTOR [3805GX] AMM 29-24-55-000-001 and AMM 29-24-55-400-001.
B. Do the test given in Para. 3