1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 29-13-00-710-052-A 4. Fault Isolation
Subtask 29-13-00-810-055-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:29:25 UTC
Loss of the Pressure of the Eng 2 Pump
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-00-00-280-006 | Check of the Green or Yellow Hydraulic System after Engine Pump Failure or Operation in a Possible Cavitation Condition - with Ground Cart Available |
| AMM 29-13-00-710-002 | Operational Test of the Yellow Hydraulic System |
| ASM 291301 | |
| AMM 29-13-17-000-040 | Removal of the Engine-Pump Pressure Switch |
| AMM 29-13-17-000-802 | Removal of the Engine-Pump Pressure Switch |
| AMM 29-13-17-400-040 | Installation of the Engine-Pump Pressure Switch |
| AMM 29-13-17-400-802 | Installation of the Engine-Pump Pressure Switch |
| AMM 29-13-51-000-003 | Removal of the Yellow Engine Pump |
| AMM 29-13-51-000-004 | Removal of the Yellow Engine Pump |
| AMM 29-13-51-000-806 | Removal of the Yellow Engine Driven Pump |
| AMM 29-13-51-100-801 | Cleaning of the Engine Pump Solenoid-Valve |
| AMM 29-13-51-100-802 | Cleaning of the Engine Pump Solenoid-Valve |
| AMM 29-13-51-100-804 | Cleaning of the Engine Pump Solenoid-Valve |
| AMM 29-13-51-400-003 | Installation of the Yellow Engine Pump |
| AMM 29-13-51-400-004 | Installation of the Yellow Engine Pump |
| AMM 29-13-51-400-806 | Installation of the Yellow Engine Driven Pump |
Subtask 29-13-00-710-052-A 4. Fault Isolation
Subtask 29-13-00-810-055-A ** ON A/C NOT FOR ALL
A. If the test gives:
1 Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
(b) If the engine pump fire valve is not closed:
a Clean the Solenoid Valve of the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-100-801.
b Do the test given in Para. 3.
c If the fault continues:
d Replace the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-000-003 and AMM 29-13-51-400-003.
e Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
Subtask 29-13-00-810-055-C ** ON A/C NOT FOR ALL - The message HYD Y ENG 2 PUMP LO PR on the upper ECAM DU
- The LO flag of the Yellow hydraulic system on the HYD page of the lower ECAM DU
- The PTU running indication on the HYD page of the lower ECAM DU
NOTE: The PRESS SW-Y PUMP, ENG 2 (3074GD) sends a low pressure signal to the ECAM system. This causes the PTU running indication on the lower ECAM DU, although the PTU does not operate (non system failure).
- The Yellow ENG 2 PUMP P/BSW FAULT light on panel 40VU:
- Look on the HYD page of the lower ECAM DU and do a check of the pressure of the Yellow system.
- Do a check on the lower ECAM DU to make sure that the engine pump fire valve 3046GK is not closed.
1 Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
NOTE: A cavitation condition of the engine pump is possible when the engine pump operates with the engine pump fire valve closed (if you set the ENG 1 (2) FIRE pushbutton on the Eng/APU fire panel), or with the reservoir below the low level (ECAM indication).
2 Push the ENG 2 FIRE P/BSW on panel 1WD (ENG/APU FIRE section on the overhead panel 20VU) to open the engine pump fire valve 3046GK. (b) If the engine pump fire valve is not closed:
- Do a check for 28 VDC between:
PUMP VARIABLE DTS [3030GD] connector A/1 and PUMP VARIABLE DTS [3030GD] connector A/3 ASM 291301.
a Clean the Solenoid Valve of the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-100-801.
b Do the test given in Para. 3.
c If the fault continues:
d Replace the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-000-003 and AMM 29-13-51-400-003.
e Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
NOTE: A cavitation condition of the engine pump is possible when the engine pumpoperates with the engine pump fire valve closed (if you set the ENG 1 (2) FIRE pushbutton on the Eng/APU fire panel), or with the reservoir below the low level (ECAM indication).
2 If there is 28 VDC: - Replace the
ENG 2 PUMP P/BSW (3703GD) .
- Do a check of the wiring between:
PUMP VARIABLE DTS [3030GD] connector A/3 and CB (3701GD) and repair the wiring as necessary ASM 291301.
- Do a check for continuity between:
the ENG-HYD.-PUMP-SW [3074GD] connector A/1 and A/3 ASM 291301.
- Replace the ENG-HYD.-PUMP-SW [3074GD] AMM 29-13-17-000-040 and AMM 29-13-17-400-040.
- Make sure that the wiring is not connected to GND between:
ENG-HYD.-PUMP-SW [3074GD] connector A/1 and the DIODE (1156VD) connector 43 ASM 291301.
- Repair the wiring as necessary.
A. If the test gives:
1 Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
(b) If the engine pump fire valve is not closed:
a Clean the Solenoid Valve of the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-100-802.
b Do the test given in Para. 3.
c If the fault continues:
d Replace the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-000-004 and AMM 29-13-51-400-004.
e Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
Subtask 29-13-00-810-055-D ** ON A/C NOT FOR ALL - The message HYD Y ENG 2 PUMP LO PR on the upper ECAM DU
- The LO flag of the Yellow hydraulic system on the HYD page of the lower ECAM DU
- The PTU running indication on the HYD page of the lower ECAM DU
NOTE: The PRESS SW-Y PUMP, ENG 2 (3074GD) sends a low pressure signal to the ECAM system. This causes the PTU running indication on the lower ECAM DU, although the PTU does not operate (non system failure).
- The Yellow ENG 2 PUMP P/BSW FAULT light on panel 40VU:
- Look on the HYD page of the lower ECAM DU and do a check of the pressure of the Yellow system.
- Do a check on the lower ECAM DU to make sure that the engine pump fire valve 3046GK is not closed.
1 Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
NOTE: A cavitation condition of the engine pump is possible when the engine pump operates with the engine pump fire valve closed (if you set the ENG 1 (2) FIRE pushbutton on the Eng/APU fire panel), or with the reservoir below the low level (ECAM indication).
2 Push the ENG 2 FIRE P/BSW on panel 1WD (ENG/APU FIRE section on the overhead panel 20VU) to open the engine pump fire valve 3046GK. (b) If the engine pump fire valve is not closed:
- Do a check for 28 VDC between:
PUMP VARIABLE DTS [3030GD] connector A/1 and PUMP VARIABLE DTS [3030GD] connector A/3 ASM 291301.
a Clean the Solenoid Valve of the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-100-802.
b Do the test given in Para. 3.
c If the fault continues:
d Replace the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-000-004 and AMM 29-13-51-400-004.
e Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
NOTE: A cavitation condition of the engine pump is possible when the engine pumpoperates with the engine pump fire valve closed (if you set the ENG 1 (2) FIRE pushbutton on the Eng/APU fire panel), or with the reservoir below the low level (ECAM indication).
2 If there is 28 VDC: - Replace the
ENG 2 PUMP P/BSW (3703GD) .
- Do a check of the wiring between:
PUMP VARIABLE DTS [3030GD] connector A/3 and CB (3701GD) and repair the wiring as necessary ASM 291301.
- Do a check for continuity between:
the ENG-HYD.-PUMP-SW [3074GD] connector A/1 and A/3 ASM 291301.
- Replace the ENG-HYD.-PUMP-SW [3074GD] AMM 29-13-17-000-040 and AMM 29-13-17-400-040.
- Make sure that the wiring is not connected to GND between:
ENG-HYD.-PUMP-SW [3074GD] connector A/1 and the DIODE (1156VD) connector 43 ASM 291301.
- Repair the wiring as necessary.
A. If the test gives:
1 Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
(b) If the engine pump fire valve is not closed:
a Clean the Solenoid Valve of the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-100-804.
b Do the test given in Para. 3.
c If the fault continues:
d Replace the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-000-806 and AMM 29-13-51-400-806.
e Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
Subtask 29-13-00-710-056-A - The message HYD Y ENG 2 PUMP LO PR on the upper ECAM DU
- The LO flag of the Yellow hydraulic system on the HYD page of the lower ECAM DU
- The PTU running indication on the HYD page of the lower ECAM DU
NOTE: The PRESS SW-Y PUMP, ENG 2 (3074GD) sends a low pressure signal to the ECAM system. This causes the PTU running indication on the lower ECAM DU, although the PTU does not operate (non system failure).
- The Yellow ENG 2 PUMP P/BSW FAULT light on panel 40VU:
- Look on the HYD page of the lower ECAM DU and do a check of the pressure of the Yellow system.
- Do a check on the lower ECAM DU to make sure that the engine pump fire valve 3046GK is not closed.
1 Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
NOTE: A cavitation condition of the engine pump is possible when the engine pump operates with the engine pump fire valve closed (if you set the ENG 1 (2) FIRE pushbutton on the Eng/APU fire panel), or with the reservoir below the low level (ECAM indication).
2 Push the ENG 2 FIRE P/BSW on panel 1WD (ENG/APU FIRE section on the overhead panel 20VU) to open the engine pump fire valve 3046GK. (b) If the engine pump fire valve is not closed:
- Do a check for 28 VDC between:
PUMP VARIABLE DTS [3030GD] connector A/1 and PUMP VARIABLE DTS [3030GD] connector A/3 ASM 291301.
a Clean the Solenoid Valve of the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-100-804.
b Do the test given in Para. 3.
c If the fault continues:
d Replace the PUMP VARIABLE DTS [3030GD] AMM 29-13-51-000-806 and AMM 29-13-51-400-806.
e Do a check of the engine pump for a possible cavitation condition AMM 29-00-00-280-006.
NOTE: A cavitation condition of the engine pump is possible when the engine pumpoperates with the engine pump fire valve closed (if you set the ENG 1 (2) FIRE pushbutton on the Eng/APU fire panel), or with the reservoir below the low level (ECAM indication).
2 If there is 28 VDC: - Replace the
ENG 2 PUMP P/BSW (3703GD) .
- Do a check of the wiring between:
PUMP VARIABLE DTS [3030GD] connector A/3 and CB (3701GD) and repair the wiring as necessary ASM 291301.
- Do a check for continuity between:
the ENG-HYD.-PUMP-SW [3074GD] connector A/1 and A/3 ASM 291301.
- Replace the ENG-HYD.-PUMP-SW [3074GD] AMM 29-13-17-000-802 and AMM 29-13-17-400-802.
- Make sure that the wiring is not connected to GND between:
ENG-HYD.-PUMP-SW [3074GD] connector A/1 and the DIODE (1156VD) connector 43 ASM 291301.
- Repair the wiring as necessary.
B. Do the test as given in Para. 3. A. to make sure that operation is correct.