W DOC AIRBUS | TSM A320F

Symbol of the Electric Pump on the ECAM Lower DU shows crossline amber with a correct System Pressure Indication


TASK 29-12-00-810-820-A
Symbol of the Electric Pump on the ECAM Lower DU shows crossline amber with a correct System Pressure Indication


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-12-00-710-001
Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication
ASM 291201
AMM 29-12-55-000-001
Removal of the Blue Electric-Pump Supply Contactor
AMM 29-12-55-400-001
Installation of the Blue Electric-Pump Supply Contactor
3. Fault Confirmation
Subtask 29-12-00-710-072-A
A. Do the operational test of the electric pump of the Blue hydraulic system AMM 29-12-00-710-001.
4. Fault Isolation
Subtask 29-12-00-810-080-A
A. If during the test, the E-pump symbol on the HYD page of the lower ECAM DU shows:
  • An amber crossline color and the system pressure is correct (more than 1450 psi (99.9740 bar)):
   (1) Replace the CONTACTOR [2705GJ] AMM 29-12-55-000-001 and AMM 29-12-55-400-001.
   (2) If the fault continues:
     (a) Make sure that the electrical connector is clean and in the correct condition.
     (b) Do a check of the wiring for a ground signal at the contactor (2705GJ-A/B7).
       1 If there is no ground signal do a check and repair the wiring between:
  • The electrical connector 2705GJ-A/B9 and the SDAC-1 [1WV1] and the SDAC-2 [1WV2] ASM 291201
Subtask 29-12-00-710-073-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:29:24 UTC