Reservoir Fluid-Level Indication replaced by amber XX for the Blue Hydraulic System
TASK 29-12-00-810-819-A
Reservoir Fluid-Level Indication replaced by amber XX for the Blue Hydraulic System
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-12-00-865-065-A
Subtask 29-12-00-810-077-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:24 UTC
Reservoir Fluid-Level Indication replaced by amber XX for the Blue Hydraulic System
1. Possible Causes
- quantity indicator of the Blue hydraulic reservoir
- quantity indicator of the Green hydraulic reservoir
- quantity indicator of the Yellow hydraulic reservoir
- wiring
- C/B-HYDRAULIC/HYD/QTY/IND [1831GQ]
terminal block (7502VT)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 29-11-00-810-815-A | Reservoir Fluid-Level Indication replaced by amber XX for the Green Hydraulic System |
| TSM TASK 29-13-00-810-818-A | Reservoir Fluid-Level Indication replaced by amber XX for the Yellow Hydraulic System |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 29-11-41-000-002 | Removal of the Quantity Indicator of the Green Hydraulic Reservoir |
| AMM 29-11-41-400-002 | Installation of the Quantity Indicator of the Green Hydraulic Reservoir |
| AMM 29-12-41-000-002 | Removal of the Quantity Indicator of the Blue Hydraulic Reservoir |
| AMM 29-12-41-400-002 | Installation of the Quantity Indicator of the Blue Hydraulic System |
| AMM 29-13-41-000-003 | Removal of the Quantity Indicator of the Yellow Hydraulic Reservoir |
| AMM 29-13-41-400-003 | Installation of the Quantity Indicator of the Yellow Hydraulic Reservoir |
| AMM 29-31-00-710-001 | Functional Check of Reservoir Low Level Warning |
| AWM 293102 | |
| AMM 31-60-00-860-001 | EIS Start Procedure |
Subtask 29-12-00-865-065-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 29-12-00-860-077-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | HYDRAULIC/HYD/QTY/IND | 1831GQ | P35 |
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) On the ECAM control panel on the center pedestal, push the HYD pushbutton switch. Make sure that the HYD page is shown on the system display of the ECAM.
(4) Look for fault indications on the lower ECAM DU.
(5) Monitor the condition of the circuit breaker 1831GQ.
4. Fault Isolation(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
AMM 31-60-00-860-001.
(3) On the ECAM control panel on the center pedestal, push the HYD pushbutton switch. Make sure that the HYD page is shown on the system display of the ECAM.
(4) Look for fault indications on the lower ECAM DU.
(5) Monitor the condition of the circuit breaker 1831GQ.
Subtask 29-12-00-810-077-A
A. If the Fault Confirmation gives:
(a) Remove the electrical connector from the quantity indicator of the Blue hydraulic reservoir .
(b) Close the circuit breaker 1831GQ:
1 If the circuit breaker 1831GQ stays closed:
a Connect the electrical connector to the quantity indicator of the Blue hydraulic reservoir.
(c) Do a check of the
(a) Do a check for continuity between:
a Repair the wiring between the CB (1831GQ) and the pin C of the terminal block (7502VT) AWM 293102.
b If the fault continues:
Subtask 29-12-00-710-071-A - The reservoir fluid level indication of the Green, Blue and Yellow hydraulic system is replaced by amber XX on the lower ECAM DU.
- The circuit breaker 1831GQ is open:
(a) Remove the electrical connector from the quantity indicator of the Blue hydraulic reservoir .
(b) Close the circuit breaker 1831GQ:
1 If the circuit breaker 1831GQ stays closed:
- Replace the quantity indicator of the Blue hydraulic reservoir AMM 29-12-41-000-002 and AMM 29-12-41-400-002.
a Connect the electrical connector to the quantity indicator of the Blue hydraulic reservoir.
(c) Do a check of the
- quantity indicator of the Green hydraulic reservoir (Ref. TSM TASK 29-11-00-810-815)
and - quantity indicator of the Yellow hydraulic reservoir (Ref. TSM TASK 29-13-00-810-818).
- for the quantity indicator of the Green hydraulic reservoir AMM 29-11-41-000-002 and AMM 29-11-41-400-002
- for the quantity indicator of the Yellow hydraulic reservoir AMM 29-13-41-000-003 and AMM 29-13-41-400-003.
(a) Do a check for continuity between:
- the CB (1831GQ) and the pin C of the terminal block (7502VT) AWM 293102.
a Repair the wiring between the CB (1831GQ) and the pin C of the terminal block (7502VT) AWM 293102.
b If the fault continues:
- Replace the C/B-HYDRAULIC/HYD/QTY/IND [1831GQ] .
- Do a check for continuity between the pin C of the terminal block (7502VT) and the pins E, J, K of the terminal block (7502VT) AWM 293102.
- Replace the
terminal block (7502VT) .
B. Do the operational test of the fluid low level warning AMM 29-31-00-710-001 to make sure that the operation is correct (no fault indications shown).