Blue Reservoir Pressure is out of Tolerance


TASK 29-12-00-810-812-A
Blue Reservoir Pressure is out of Tolerance


1. Possible Causes
  • PRESSURE REDUCING VALVE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 12-32-29-281-001
Hydraulic Fluid Sample of Green, Blue and Yellow Systems for Analysis
AMM 29-00-00-864-001
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
AMM 29-14-00-720-001
Functional Test of the Pressurizing System of the Hydraulic Reservoirs
AMM 29-14-43-000-001
Removal of the Pressure Reducing Valve
AMM 29-14-43-400-001
Installation of the Pressure Reducing Valve
AMM 32-12-00-010-001
Open the Main Gear Doors for Access
3. Fault Confirmation
Subtask 29-12-00-865-058-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
121VUHYDRAULIC/HYD POWER/Y3803GXN30
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 29-12-00-860-062-A
B. Aircraft Maintenance Configuration
   (1) Depressurize the Green, Yellow and Blue hydraulic systems, but not the reservoirs AMM 29-00-00-864-001.
   (2) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the hydraulic systems:
  • in the flight compartment on the hydraulic section 40VU of the overhead panel,
  • on the ground service panels of the Green, Yellow and Blue hydraulic systems.
   (3) Open the access doors 196BB and 197FB.
   (4) Open the right main door of the main landing gear AMM 32-12-00-010-001.
   (5) Read the pressure gages (1383GM, 2383GM, 3383GM) on each hydraulic reservoir.
   (6) If the reservoir pressure indication is more than 52 +2 psi or -2 psi (3.5853 +0.1379 bar or -0.1379 bar):
     (a) Do the functional test of the pressurizing system of the hydraulic reservoirs AMM 29-14-00-720-001.
4. Fault Isolation
Subtask 29-12-00-810-063-A
A. If the reservoir pressure increases during the test to more than 50 +2 psi or -2 psi (3.4474 +0.1379 bar or -0.1379 bar):
   (1) Replace the PRESSURE REDUCING VALVE AMM 29-14-43-000-001 and AMM 29-14-43-400-001.
   (2) Take a fluid sample from each hydraulic system to make sure that the contamination of the hydraulic fluid is in the approved values AMM 12-32-29-281-001.
Subtask 29-12-00-720-050-A
B. Do the functional test of the pressurizing system of the hydraulic reservoirs again to make sure that the function is correct AMM 29-14-00-720-001.
5. Close-up
Subtask 29-12-00-865-059-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
121VUHYDRAULIC/HYD POWER/Y3803GXN30
123VUB HYD/ELEC PUMP2701GJAB09
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03