Fault of the System Pressure Indication of the Blue Hydraulic System on the ECAM Lower DU
TASK 29-12-00-810-809-A
Fault of the System Pressure Indication of the Blue Hydraulic System on the ECAM Lower DU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 29-12-00-710-061-A 4. Fault Isolation
Subtask 29-12-00-810-060-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:22 UTC
Fault of the System Pressure Indication of the Blue Hydraulic System on the ECAM Lower DU
1. Possible Causes
- HYDR. PRESSURE TRANSMITTER [2065GN]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-12-00-710-001 | Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication |
| AMM 29-32-11-000-002 | Removal of the Hydraulic Pressure Transducer |
| AMM 29-32-11-400-002 | Installation of the Hydraulic Pressure Transducer |
Subtask 29-12-00-710-061-A 4. Fault Isolation
Subtask 29-12-00-810-060-A
A. If, during the test, the operation of the flight controls is correct, but the HYD page on the ECAM lower DU shows for the Blue hydraulic system the subsequent condition:
the system pressure indication in amber (less than 1450 PSI),
the system pressure identification (BLUE) in white,
the system arrow in green.
Subtask 29-12-00-710-062-A the system pressure indication in amber (less than 1450 PSI),
the system pressure identification (BLUE) in white,
the system arrow in green.
- replace the HYDR. PRESSURE TRANSMITTER [2065GN] AMM 29-32-11-000-002 and AMM 29-32-11-400-002.
B. Do the test given in Para. 3