W DOC AIRBUS | TSM A320F

Fault of the System Pressure Indication of the Blue Hydraulic System on the ECAM Lower DU


TASK 29-12-00-810-809-A
Fault of the System Pressure Indication of the Blue Hydraulic System on the ECAM Lower DU


1. Possible Causes
  • HYDR. PRESSURE TRANSMITTER [2065GN]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-12-00-710-001
Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication
AMM 29-32-11-000-002
Removal of the Hydraulic Pressure Transducer
AMM 29-32-11-400-002
Installation of the Hydraulic Pressure Transducer
3. Fault Confirmation
Subtask 29-12-00-710-061-A
A. Do the operational test of the electric pump of the Blue hydraulic system AMM 29-12-00-710-001.
4. Fault Isolation
Subtask 29-12-00-810-060-A
A. If, during the test, the operation of the flight controls is correct, but the HYD page on the ECAM lower DU shows for the Blue hydraulic system the subsequent condition:
the system pressure indication in amber (less than 1450 PSI),
the system pressure identification (BLUE) in white,
the system arrow in green.
Subtask 29-12-00-710-062-A
B. Do the test given in Para. 3
[Rev.8 from Aug 2018] 2026.04.04 04:29:22 UTC