Overheat Indication of the Blue Electric Pump
TASK 29-12-00-810-806-A
Overheat Indication of the Blue Electric Pump
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 29-12-00-710-057-A 4. Fault Isolation
Subtask 29-12-00-810-056-A
[Rev.8 from Aug 2018]
2026.04.04 04:29:22 UTC
Overheat Indication of the Blue Electric Pump
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 29-10-00-210-002 | Check of the Clogging Indicators of the Hydraulic System Filters (Other than the two Case Drain Filters of the Engine-Driven Pumps) |
| AMM 29-12-00-710-001 | Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication |
| AMM 29-12-51-000-001 | Removal of the Electric Pump |
| AMM 29-12-51-400-001 | Installation of the Electric Pump |
| AMM 29-24-51-000-001 | Removal of the Electric Pump |
| AMM 29-24-51-400-001 | Installation of the Electric Pump |
Subtask 29-12-00-710-057-A 4. Fault Isolation
Subtask 29-12-00-810-056-A
A. HYD B ELEC PUMP OVHT Message
(1) If the test gives the message HYD B ELEC PUMP OVHT on the upper ECAM DU:
Subtask 29-12-00-710-058-A (1) If the test gives the message HYD B ELEC PUMP OVHT on the upper ECAM DU:
- Disconnect the electrical connector (2075GJ-A) and look at the upper ECAM DU.
- Do a check of the wiring between the PACKAGE E-PUMP [2075GJ] connector A/F and the SDAC.
- Do a check of the CASE DRAIN FILT.ELEC.PUMP B [2084GM] AMM 29-10-00-210-002.
- Replace the PACKAGE E-PUMP [2075GJ] AMM 29-12-51-000-001 and AMM 29-12-51-400-001.
- Replace the ELEC PUMP-B (2075GJ) with the ELEC PUMP-Y (3075GX) which is interchangeable, if a new pump is not available AMM 29-24-51-000-001 and AMM 29-24-51-400-001.
B. Do the test as given in Para. 3. A. to make sure that the operation is correct.