Overheat Indication of the Blue Electric Pump


TASK 29-12-00-810-806-A
Overheat Indication of the Blue Electric Pump


1. Possible Causes
  • wiring
  • PACKAGE E-PUMP [2075GJ]
  • CASE DRAIN FILT.ELEC.PUMP B [2084GM]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-10-00-210-002
Check of the Clogging Indicators of the Hydraulic System Filters (Other than the two Case Drain Filters of the Engine-Driven Pumps)
AMM 29-12-00-710-001
Functional Check of Blue Electrical Pump Pressure by Reading ECAM Indication
AMM 29-12-51-000-001
Removal of the Electric Pump
AMM 29-12-51-400-001
Installation of the Electric Pump
AMM 29-24-51-000-001
Removal of the Electric Pump
AMM 29-24-51-400-001
Installation of the Electric Pump
3. Fault Confirmation
Subtask 29-12-00-710-057-A
A. Do the operational test of the electric pump of the Blue hydraulic system AMM 29-12-00-710-001.
4. Fault Isolation
Subtask 29-12-00-810-056-A
A. HYD B ELEC PUMP OVHT Message
   (1) If the test gives the message HYD B ELEC PUMP OVHT on the upper ECAM DU:
  • Disconnect the electrical connector (2075GJ-A) and look at the upper ECAM DU.
   (2) If the upper ECAM DU show the message HYD B ELEC PUMP OVHT:
  • Do a check of the wiring between the PACKAGE E-PUMP [2075GJ] connector A/F and the SDAC.
   (3) If the upper ECAM DU does not show the message HYD B ELEC PUMP OVTH:
   (4) If the fault continues:
Subtask 29-12-00-710-058-A
B. Do the test as given in Para. 3. A. to make sure that the operation is correct.